Assessment of Cable Length Limit for Effective Protection by Z-Source Circuit Breakers in DC Power Networks

Abstract: This paper introduces groundbreaking research on how to assess the Cable Length Limit (CLL) to ensure effective protection by Z-source Circuit Breakers (ZCBs) in DC power networks. It has been revealed that the line parameters of power cables have a significant impact on the cutoff performance of ZCBs. The question of assessing the CLL has been raised as an unsolved problem. In this paper, a method of CLL assessment is proposed based on physical models and simulation tests. To verify the proposed method, two s… Show more

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
3

Citation Types

0
3
0

Year Published

2022
2022
2024
2024

Publication Types

Select...
5

Relationship

0
5

Authors

Journals

citations
Cited by 5 publications
(3 citation statements)
references
References 28 publications
0
3
0
Order By: Relevance
“…The current‐limiting reactor (CLR) is currently the most used and practical method for limiting the fault current, since it has excellent fault current limiting performance, simple structure and low implementation cost [21]. However, since the CLRs enlarge the inductance of the fault loop, the fault current clearance time and the dissipated energy of the DCCB are significantly increased [22,23]. This will lead to the delayed recovery of the healthy network and increased heat dissipation of the equipment.…”
Section: Introductionmentioning
confidence: 99%
“…The current‐limiting reactor (CLR) is currently the most used and practical method for limiting the fault current, since it has excellent fault current limiting performance, simple structure and low implementation cost [21]. However, since the CLRs enlarge the inductance of the fault loop, the fault current clearance time and the dissipated energy of the DCCB are significantly increased [22,23]. This will lead to the delayed recovery of the healthy network and increased heat dissipation of the equipment.…”
Section: Introductionmentioning
confidence: 99%
“…Yang, W et al analyzed the effect of pressure, relative humidity, and temperature difference on MCB according to altitude through simulation [6]. In addition, various studies on LV or MV breakers are being conducted, and in particular, studies related to the DC system are increasing [7][8][9][10][11][12][13].…”
Section: Introductionmentioning
confidence: 99%
“…Particularly, in the case of DC distribution products where the electrical resistance is more fragile than that of the AC distribution products, it is necessary to interrupt the inflow of over-current more quickly. Therefore, various studies are being conducted to improve performance, such as introducing a new structure to improve the performance of existing breakers [4][5][6][7][8][9][10][11][12].…”