2009
DOI: 10.1038/bmt.2009.182
|View full text |Cite
|
Sign up to set email alerts
|

Assessment of CD4 T-lymphocyte reactivity by the Cylex ImmuKnow assay in patients following allogeneic hematopoietic SCT

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
4
1

Citation Types

0
6
0
2

Year Published

2010
2010
2021
2021

Publication Types

Select...
9

Relationship

1
8

Authors

Journals

citations
Cited by 16 publications
(8 citation statements)
references
References 23 publications
0
6
0
2
Order By: Relevance
“…The Cylex ImmuKnow ® is another immune monitoring assay, which after stimulation with PHA measures intracellular adenosine triphosphate levels in CD4+ T-cells ( 24 ). Several studies in the HSCT population did not demonstrate any additional clinical value of the ImmunKnow assay ( 11 , 25 , 26 ). More complex biomarkers such as T-cell immunoglobulin and mucin-domain containing 3 (TIM3), interleukin-6, soluble tumor necrosis factor receptor 1, and plasma suppression of tumorigenicity 2 have shown some promise in predicting AGVHD and NRM ( 3 , 5 ).…”
Section: Discussionmentioning
confidence: 96%
“…The Cylex ImmuKnow ® is another immune monitoring assay, which after stimulation with PHA measures intracellular adenosine triphosphate levels in CD4+ T-cells ( 24 ). Several studies in the HSCT population did not demonstrate any additional clinical value of the ImmunKnow assay ( 11 , 25 , 26 ). More complex biomarkers such as T-cell immunoglobulin and mucin-domain containing 3 (TIM3), interleukin-6, soluble tumor necrosis factor receptor 1, and plasma suppression of tumorigenicity 2 have shown some promise in predicting AGVHD and NRM ( 3 , 5 ).…”
Section: Discussionmentioning
confidence: 96%
“…In addition, results cannot be extrapolated to haploidentical and cord blood patients as, at the time of performance of the study, there were few such donors utilized at our center. Assessing what impact these alternative donors have on the QFM assay would be important, given the different immune recovery profiles of these alternative transplants . Finally, immune function in later phases of an alloHCT has not been explored in this study; however, a cross‐sectional study assessing IFN‐γ levels in QFM assay at later time points post‐transplant is currently underway at our center.…”
Section: Discussionmentioning
confidence: 99%
“…Currently, tests that assess immune reconstitution and hence risk of infection consist primarily of lymphocyte subset analyses and immunoglobulin levels. These are not functional tests and may not accurately measure immune recovery . There is therefore an unmet need for a non‐invasive, simple test to help predict or detect the early development of infection and GVHD and help titrate the immunosuppression required to avoid toxicities and infections.…”
Section: Introductionmentioning
confidence: 99%
“… studied its relevance in the context of autologous HCT and is therefore not instructive for our study of patients going through allogeneic HCT. Thus far, only one publication has described utilization of the ImmuKnow assay for immune monitoring post‐allogeneic HCT . However, there are several apparent differences between the latter and the current study.…”
Section: Discussionmentioning
confidence: 79%