2012
DOI: 10.1016/j.anucene.2012.03.014
|View full text |Cite
|
Sign up to set email alerts
|

Assessment of gamma-rays generated by the spontaneous fission source 252Cf using a Monte Carlo method

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
1

Citation Types

1
7
0

Year Published

2012
2012
2022
2022

Publication Types

Select...
8

Relationship

0
8

Authors

Journals

citations
Cited by 20 publications
(8 citation statements)
references
References 12 publications
1
7
0
Order By: Relevance
“…This is to reduce the weight of the proposed device due to the radiological shielding requirements and the total neutron and photon dose rate for the operator. The measured and normalized neutron spectra of 252 Cf were taken from (Griffith et al, 1990), while the spectra of the gamma-ray photons associated with the 252 Cf source were taken from (Khabaz, 2012). To remove the gamma-ray photons associated with the 252 Cf source, it was located inside a sphere of Pb with 1 cm inner radius and 3 cm outer radius.…”
Section: Geometrymentioning
confidence: 99%
“…This is to reduce the weight of the proposed device due to the radiological shielding requirements and the total neutron and photon dose rate for the operator. The measured and normalized neutron spectra of 252 Cf were taken from (Griffith et al, 1990), while the spectra of the gamma-ray photons associated with the 252 Cf source were taken from (Khabaz, 2012). To remove the gamma-ray photons associated with the 252 Cf source, it was located inside a sphere of Pb with 1 cm inner radius and 3 cm outer radius.…”
Section: Geometrymentioning
confidence: 99%
“…Neutron detection is mainly based on gas counters, scintillators, or semiconductors. As mentioned in Ref [2], the A Gd ( 155 Gd and 157 Gd), 10 B, 7 Li are three kinds of elements having the highest neutron absorption cross section. Compared with 10B and 7 Li, the cross section for A Gd to capture neutron drops more rapidly with the increase of the neutron velocity, which makes it more suitable for thermal neutron detection.…”
Section: Introductionmentioning
confidence: 99%
“…Compared with 10B and 7 Li, the cross section for A Gd to capture neutron drops more rapidly with the increase of the neutron velocity, which makes it more suitable for thermal neutron detection. Recently the scintillators containing 6 Li or 10 B such as the LYSO crystal are proven to have a relatively high neutron detection efficiency and serve as good alternatives for 3 He gas proportional counters [3]. It can also achieve a great 𝑛/𝛾 discrimination through the pulse shape discrimination (PSD) method.…”
Section: Introductionmentioning
confidence: 99%
“…3 shows the gamma spectrum of a Cf source in dashed line, from data of ref. [33], and in continuous line the attenuated spectrum by using a 10 cm lead shield between the source and the detector. This shows how we avoid most of the gammas coming from the source to enter into the detector, leaving mainly fast neutrons emitted by the source.…”
mentioning
confidence: 99%
“…Figure3: Gamma spectrum emitted by a 252 Cf source taken from reference[33], in dashed line and the attenuated spectrum by the 10 cm lead shield in continuous line[34].…”
mentioning
confidence: 99%