2011
DOI: 10.1039/c1an15396j
|View full text |Cite
|
Sign up to set email alerts
|

Asymmetric logistic peak as a suitable function for the resolution of highly asymmetric voltammograms in non-bilinear systems

Abstract: The asymmetric logistic peak is tested as a new function for the parametric signal fitting (PSF) of highly asymmetric electrochemical signals in non-bilinear datasets, such as those obtained in linear sweep voltammetry (LSV) or in the presence of irreversible electrochemical processes. This new multivariate curve resolution strategy (PSF-ALPA) is successfully applied to LS voltammograms measured for the Cd(II)-glutathione system with a hanging mercury drop electrode, where Cd(II) is reversibly reduced, and to … Show more

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
1
1
1

Citation Types

0
13
0

Year Published

2013
2013
2019
2019

Publication Types

Select...
6
1

Relationship

1
6

Authors

Journals

citations
Cited by 20 publications
(13 citation statements)
references
References 21 publications
0
13
0
Order By: Relevance
“…Such a numeric approach helps to perform peaks separation, background correction, and may be regarded as an effective signal filtering. Peaks affected by diffusion limitations have asymmetric shape and requires elaborated numerical models . Voltammetric peaks of adsorbed systems are symmetrical, but simulation of these peaks is complicated by lateral interactions.…”
Section: Introductionmentioning
confidence: 90%
“…Such a numeric approach helps to perform peaks separation, background correction, and may be regarded as an effective signal filtering. Peaks affected by diffusion limitations have asymmetric shape and requires elaborated numerical models . Voltammetric peaks of adsorbed systems are symmetrical, but simulation of these peaks is complicated by lateral interactions.…”
Section: Introductionmentioning
confidence: 90%
“…The asymmetric logistic peak adjustment (ALPA) was developed as a new function for the PSF of highly asymmetric electrochemical signals in non-bilinear datasets or in the presence of irreversible electrochemical processes [63]. Fig.…”
Section: Figurementioning
confidence: 99%
“…Some of the main differences among them are as follows: (1) whether alignment is performed using the continuous signal or individually detected peaks, (2) whether or not signal intensity is used, and (3) whether or not scale changes are corrected. The most important alignment methods that have been employed for aligning the voltammograms are COW, icoshift, GPA, GPA2D, ALPA, shiftfit and pHfit [58][59][60][61][62][63]65,83,116,117,119,120].…”
Section: Potential Shift Correctionmentioning
confidence: 99%
“…After holding 11 AICWs, significant progress has been achieved towards the two main goals of its foundation. Today, many Iranian chemists (especially analytical chemists) are familiar with chemometrics methods, and Iranian chemometricians have scientific collaborations with different chemometrics research groups around the world [3,4,6,[8][9][10][11][12][13][14][15][16][17][18][19][20]. Some of expert chemometricians have visited Iran.…”
Section: Workhops and Seminarsmentioning
confidence: 99%