2002
DOI: 10.1046/j.1525-1594.2002.00909.x
|View full text |Cite
|
Sign up to set email alerts
|

Asymptomatic Prosthetic Valve Dysfunction: Pannus?

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
3
1

Citation Types

0
8
0

Year Published

2003
2003
2015
2015

Publication Types

Select...
5

Relationship

3
2

Authors

Journals

citations
Cited by 5 publications
(8 citation statements)
references
References 5 publications
0
8
0
Order By: Relevance
“…Small valve size (B19 mm), a specific valve type (Carbomedics), an etiology of rheumatic valve disease, and young age at the time of AVR (\48.8 years) were found to be independent predictors of moderate to severe pannus. The incidence of prosthetic valve obstruction due to pannus has been known to be uncommon (0.1-4.5 % per patient-year in the aortic position) [3,12,16], but recent studies have found that prosthetic aortic valve obstruction caused by pannus is more frequent than previously reported and can be detected even in asymptomatic patients [17,18]. In our study, pannus formation was present in most cases (77.2 %), even in cases which showed a normal range of PG on TTE (71.4 %).…”
Section: Discussionmentioning
confidence: 99%
“…Small valve size (B19 mm), a specific valve type (Carbomedics), an etiology of rheumatic valve disease, and young age at the time of AVR (\48.8 years) were found to be independent predictors of moderate to severe pannus. The incidence of prosthetic valve obstruction due to pannus has been known to be uncommon (0.1-4.5 % per patient-year in the aortic position) [3,12,16], but recent studies have found that prosthetic aortic valve obstruction caused by pannus is more frequent than previously reported and can be detected even in asymptomatic patients [17,18]. In our study, pannus formation was present in most cases (77.2 %), even in cases which showed a normal range of PG on TTE (71.4 %).…”
Section: Discussionmentioning
confidence: 99%
“…Transvalvular peak pressure gradient (mm Hg) and effective orifice area (cm 2 ) were measured by Doppler echo. Then, open angle cineradiography (Integris BH 5000, Philips Medical Systems, Eindhoven, The Netherlands) was examined in order to assess the patients' valve function (12,13).…”
Section: Methodsmentioning
confidence: 99%
“…We diagnosed 35 patients (18.7%) with PVD with deterioration of the prosthetic valve function measured by Doppler echocardiography, and obstruction of the open angle (normal: 11.0 ± 1.4 degrees) by cineradiography was calculated as the distance between the two leaflets in the fully open position greater than 20 degrees (12,13,16). Thirty patients who ranged from 15 to 19 degrees in cineradiography were excluded.…”
Section: Methodsmentioning
confidence: 99%
See 2 more Smart Citations