2022
DOI: 10.1109/lwc.2022.3170095
|View full text |Cite
|
Sign up to set email alerts
|

Asymptotic MIMO Channel Model for Diffusive MC With Fully-Absorbing Receivers

Abstract: In a recent paper it has been shown that to model a diffusive molecular communication (MC) channel with multiple fully absorbing (FA) receivers, these can be interpreted as sources of negative particles from the other receivers' perspective. The barycenter point is introduced as the best position where to place the negative sources. The barycenter is obtained from the spatial mean of the molecules impinging on the surface of each FA receiver. This paper derives an expression that captures the position of th… Show more

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
2
1

Citation Types

0
7
0

Year Published

2023
2023
2024
2024

Publication Types

Select...
4
3

Relationship

0
7

Authors

Journals

citations
Cited by 8 publications
(7 citation statements)
references
References 31 publications
0
7
0
Order By: Relevance
“…Those points are also the center of each ring. We can take the weighted sum of the coordinate of the circles' centers on the diameter of the sphere aligned with the transmitter as (24). The numerator of ( 24) is the weighted sum of the points on the diameter of the receiver, which includes the radius of the receiver in the direction of the transmitter.…”
Section: A Barycenter In Sitomentioning
confidence: 99%
See 1 more Smart Citation
“…Those points are also the center of each ring. We can take the weighted sum of the coordinate of the circles' centers on the diameter of the sphere aligned with the transmitter as (24). The numerator of ( 24) is the weighted sum of the points on the diameter of the receiver, which includes the radius of the receiver in the direction of the transmitter.…”
Section: A Barycenter In Sitomentioning
confidence: 99%
“…Fig. 2 compares the empirical γ obtained from the PBS based on different simulation step times with the analytical γ from (24). The PBS data was obtained through a Monte Carlo simulation for 100 trials with simulation step time {10 −7 , 10 −5 , 10 −4 , 10 −3 } 1 s and diffusion coefficient 79.4 µm 2 /s.…”
Section: A Barycenter In Sitomentioning
confidence: 99%
“…where L {f } = f and L {N } = N . Next, we use the final value theorem to achieve the temporal asymptotic behavior, as t → ∞, of FA receivers' observation [9] …”
Section: System Modelmentioning
confidence: 99%
“…Thus, barycenters of receivers are assumed to be at the centers of the spherical FA receivers, as t → ∞. Hence, d i,j is approximated as the distance between the center of R i and R j [9].…”
Section: System Modelmentioning
confidence: 99%
See 1 more Smart Citation