ATP measurement as an objective method to measure environmental contamination in 9 hospitals in the Dutch/Belgian border area.

Abstract: Background The objective of this study was to determine the level of environmental contamination in hospitals in the Dutch/Belgian border area, using ATP measurements. Design A cross-sectional observational survey Methods Standardized ATP measurements were conducted in 9 hospitals on 32 hospital wards. Thirty pre-defined surfaces per hospital ward were measured with the 3M Clean Trace NG luminometer. Results are displayed in relative light units (RLU). RLU >1000 was considered as “not clean.” Differences in… Show more

Help me understand this report
View published versions

Search citation statements

Order By: Relevance

Paper Sections

Select...
1
1

Citation Types

0
2
0

Year Published

2020
2020
2021
2021

Publication Types

Select...
1
1

Relationship

2
0

Authors

Journals

citations
Cited by 2 publications
(2 citation statements)
references
References 11 publications
0
2
0
Order By: Relevance
“…On each ward, ATP measurements were performed on a selection of 30 pre-de ned fomites. 9 These fomites were classi ed into 4 different groups: medical devices, patient bound materials, sanitary items and ward bound materials. Fomites were chosen based on the following criteria: frequently touched by nursing staff or patients or being in the direct vicinity of patients or high risk surfaces (e.g.…”
Section: Settingmentioning
confidence: 99%
See 1 more Smart Citation
“…On each ward, ATP measurements were performed on a selection of 30 pre-de ned fomites. 9 These fomites were classi ed into 4 different groups: medical devices, patient bound materials, sanitary items and ward bound materials. Fomites were chosen based on the following criteria: frequently touched by nursing staff or patients or being in the direct vicinity of patients or high risk surfaces (e.g.…”
Section: Settingmentioning
confidence: 99%
“…The RLU < 1000 breakpoint for cleanliness was de ned for measuring a fomite at a random point during the day as described in van Arkel, el al. 9 An RLU value above 1000 RLU was categorized as unclean or intermediate, above 3000 RLU as dirty.…”
Section: Atp Measurements and Rlu Breakpointsmentioning
confidence: 99%