2004
DOI: 10.1016/j.watres.2004.04.043
|View full text |Cite
|
Sign up to set email alerts
|

Atrazine removal using adsorption and electrochemical regeneration

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
1
1
1

Citation Types

1
70
0

Year Published

2009
2009
2024
2024

Publication Types

Select...
7
1
1

Relationship

0
9

Authors

Journals

citations
Cited by 103 publications
(71 citation statements)
references
References 25 publications
1
70
0
Order By: Relevance
“…If Nyex 100 is electrochemically regenerated using cathode and anode, and salt. However, the adsorption isotherm was similar to when using fresh Nyex 100 (Brown et al, 2004). Adsorption isotherms were determined using Filtrasorb 400 (Chemviron Carbon) and two resins: Dowex Optipore L 493 (Dow Chemical Company) and Lewatit VP OC 1064 MD PH.…”
Section: Pesticide Removal Achievements By Adsorptionmentioning
confidence: 94%
“…If Nyex 100 is electrochemically regenerated using cathode and anode, and salt. However, the adsorption isotherm was similar to when using fresh Nyex 100 (Brown et al, 2004). Adsorption isotherms were determined using Filtrasorb 400 (Chemviron Carbon) and two resins: Dowex Optipore L 493 (Dow Chemical Company) and Lewatit VP OC 1064 MD PH.…”
Section: Pesticide Removal Achievements By Adsorptionmentioning
confidence: 94%
“…Nyex , contained above 90% carbon and had a particle size range of 100 to 700 µm [18][19][20][21][22][23]. The Nyex TM was washed with tap water several times prior to use.…”
Section: Materials/reagents and Sample Preparationmentioning
confidence: 99%
“…The process uses a low capacity graphitic material (a graphite intercalation compound; Nyex TM (Cheshire, UK), a material comprising both graphitic edges and basal planes which are believed to provide a range of adsorption sites) as an effective adsorbent that can be rapidly and cost-effectively regenerated electrochemically [20][21][22]. Although a relatively low sorption capacity material, the lack of intra-granular porosity provides for both rapid sorption and regeneration kinetics, whilst the relatively high electrical conductivity means that electrochemical regeneration could potentially be carried out using relatively little energy [23].…”
Section: Introductionmentioning
confidence: 99%
“…However, the adsorption kinetics of these materials is very fast [10], [11]. The higher electrical conductivity of the GIC material has made it an appropriate material for electrochemical regeneration.…”
Section: Introductionmentioning