Attenuated Total Reflection-Fourier Transform Infrared (ATR-FTIR) Spectroscopy Analysis of Saliva for Breast Cancer Diagnosis

Abstract: Saliva biomarkers using reagent-free biophotonic technology have not been investigated as a strategy for early detection of breast cancer (BC). The attenuated total reflection-Fourier transform infrared (ATR-FTIR) spectroscopy has been proposed as a promising tool for disease diagnosis. However, its utilization in cancer is still incipient, and currently saliva has not been used for BC screening. We have applied ATR-FTIR onto saliva from patients with breast cancer, benign breast disease, and healthy matched c… Show more

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
1
1
1

Citation Types

1
43
0
1

Year Published

2020
2020
2022
2022

Publication Types

Select...
9

Relationship

2
7

Authors

Journals

citations
Cited by 76 publications
(45 citation statements)
references
References 50 publications
1
43
0
1
Order By: Relevance
“…The air spectra was used as a background in ATR-FTIR analysis. Sample spectra and background was taken with 4 cm -1 of resolution and 32 scans were performed for salivary analysis [52,53].…”
Section: Chemical Profile In Stimulated Saliva By Atr-ftir Spectroscopymentioning
confidence: 99%
“…The air spectra was used as a background in ATR-FTIR analysis. Sample spectra and background was taken with 4 cm -1 of resolution and 32 scans were performed for salivary analysis [52,53].…”
Section: Chemical Profile In Stimulated Saliva By Atr-ftir Spectroscopymentioning
confidence: 99%
“…When used in combination with Attenuated Total Reflection Fourier Transform Infrared (ATR-FTIR) spectroscopy, these technique could provide rapid, robust and stable sample analysis. ATR-FTIR spectroscopy has already been used to detect biochemical constituents of whole blood [12][13][14], as well as other biological fluid components with high accuracy and sensitivity (which is application specific, more than 90% [15] and >70% [16]), suited to clinical decision making even on un-treated samples. However, the major fundamental limitation of this technique is selectivity towards the analyte of concern in a pool of similar chemical constituents, especially as found in whole blood [17].…”
Section: Introductionmentioning
confidence: 99%
“…The ATR unit was cleaned and dried every time, previous to the next infrared analysis. The plasma samples were dried using airflow on ATR-crystal for 3 min before obtaining the sample spectra over the range of 4000 to 400 cm −1 in a room with a controlled temperature 21–23 °C [ 38 , 39 ].…”
Section: Methodsmentioning
confidence: 99%
“…The second derivative generates valleys from the original absorption spectrum. Therefore, the analyzed wavenumbers in the second derivative are the height of valleys [ 38 , 40 ].…”
Section: Methodsmentioning
confidence: 99%