2020
DOI: 10.1088/1361-6455/ab92bf
|View full text |Cite
|
Sign up to set email alerts
|

Attosecond pulse generation at ELI-ALPS 100 kHz repetition rate beamline

Abstract: We generate attosecond pulse train (APT) in argon driven by the high repetition rate (HR) laser of the extreme light infrastructure-attosecond light pulse source (ELI-ALPS), providing 100 kHz, 80 W, 1030 nm, 40 fs pulses from a fiber chirped-pulse amplification (fiber-CPA) laser system. Under the current operating conditions of the high harmonic generation beamline (HR-GHHG), we observed the average pulse duration to be 395 as measured using the technique of reconstruction of attosecond beating by interference… Show more

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
1
1

Citation Types

2
36
0

Year Published

2021
2021
2023
2023

Publication Types

Select...
7

Relationship

3
4

Authors

Journals

citations
Cited by 37 publications
(38 citation statements)
references
References 115 publications
2
36
0
Order By: Relevance
“…However, with the increase of laser power, this portion will become stronger and it must be considered. In the high-repetition rate regime of ~100 kHz, several laboratories have used annular laser beams to generate high-order harmonics [27,70], while the measurement of the attosecond temporal duration was only reported in our previous work at ELI-ALPS [52].…”
Section: Generation Beam (Xuv Arm)mentioning
confidence: 99%
See 1 more Smart Citation
“…However, with the increase of laser power, this portion will become stronger and it must be considered. In the high-repetition rate regime of ~100 kHz, several laboratories have used annular laser beams to generate high-order harmonics [27,70], while the measurement of the attosecond temporal duration was only reported in our previous work at ELI-ALPS [52].…”
Section: Generation Beam (Xuv Arm)mentioning
confidence: 99%
“…We make this distinction because temporal characterization is a demonstration of the attosecond pump-probe capability. As shown in Figure 1, single-pass HHG can provide high harmonics [17][18][19][20][21][22][23][24][25][26][27][28][29][30][31][32][33][34][35][36] up to tens of nJ per shot at 1 MHz by using powerful driving lasers with an average power up to ~100 W [37][38][39][40][41][42][43] and the attosecond pulses [44][45][46][47][48][49][50][51][52][53][54][55] up to hundreds of pJ per shot at 100 kHz. Intracavity HHG can deliver the high harmonics with the repetition rates up to hundreds of MHz [56][57][58][59][60][61][62][63].…”
Section: Introductionmentioning
confidence: 99%
“…The experiments are performed using the HR GHHG GAS beamline of the Extreme Light Infrastructure-Attosecond Light Pulse Source (ELI-ALPS) Research Facility [2,37]. The high-harmonic generation beamline [37] is seeded by one of the user-ready laser sources of ELI-ALPS [38]: the high-repetition-rate (HR-1) laser system is specified to emit 1 mJ, sub-2-cycle pulses at 1030 nm [38]. The heart of the system is a powerful subpicosecond ytterbium fiber-based chirped pulse amplifier (CPA).…”
mentioning
confidence: 99%
“…Compared with the beamline configuration detailed by Ye et al in Ref. [37] only a minor modification is made on the beamline (Fig. 1): one of the steering mirrors is replaced by a custom-made SDU [39], while the other optics remain unchanged.…”
mentioning
confidence: 99%
See 1 more Smart Citation