Autocorrelated Differential Algorithm for Real-Time Seismocardiography Analysis

Abstract: We present a novel seismocardiography (SCG)based approach for real-time cardio-respiratory activity measurement called the Autocorrelated Differential Algorithm (ADA). Measurements were performed on ten male subjects in the supine position for three 7-minute-long sets each, corresponding to 14,619 heartbeats. The ADA utilized temporal variations, windowing, and autocorrelation to produce physiological measurements corresponding to heart rate (HR), and left ventricular ejection time, and estimations of respirat… Show more

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
1
1
1
1

Citation Types

0
21
0

Year Published

2019
2019
2025
2025

Publication Types

Select...
3
3

Relationship

0
6

Authors

Journals

citations
Cited by 18 publications
(21 citation statements)
references
References 58 publications
0
21
0
Order By: Relevance
“…The trade-off can be seen in Figure 8 for sampling frequencies of 50 Hz, 100 Hz, 150 Hz, 200 Hz, and 250 Hz. Interestingly, the compromise in accuracy for VCG resulted in a r 2 value of 0.9456 at 50 Hz, which marked a significant improvement over SCG alone [33]. A maximum computational fraction of 0.088 s per second of data was observed at a sampling frequency of 250 Hz when using a standard desktop computer with no external programs activated.…”
Section: Resultsmentioning
confidence: 99%
See 4 more Smart Citations
“…The trade-off can be seen in Figure 8 for sampling frequencies of 50 Hz, 100 Hz, 150 Hz, 200 Hz, and 250 Hz. Interestingly, the compromise in accuracy for VCG resulted in a r 2 value of 0.9456 at 50 Hz, which marked a significant improvement over SCG alone [33]. A maximum computational fraction of 0.088 s per second of data was observed at a sampling frequency of 250 Hz when using a standard desktop computer with no external programs activated.…”
Section: Resultsmentioning
confidence: 99%
“…The monitor delivered measurements of averaged and instantaneous heart rate for such subjects at rest and under physical exertion. Cardiac mechanical activity was measured by an upgraded version of the ADA [33] that processed cardiac-induced sternal vibrations as VCG signals. The measurements were referenced with ECG that measured the electrical activity of the heart using the standard Pan Tompkins [57] algorithm for the ECG signal analysis.…”
Section: Discussionmentioning
confidence: 99%
See 3 more Smart Citations