2014
DOI: 10.1109/tmi.2014.2303782
|View full text |Cite
|
Sign up to set email alerts
|

Automated Aortic Doppler Flow Tracing for Reproducible Research and Clinical Measurements

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
1
1
1

Citation Types

0
28
0

Year Published

2015
2015
2023
2023

Publication Types

Select...
8

Relationship

2
6

Authors

Journals

citations
Cited by 24 publications
(28 citation statements)
references
References 27 publications
0
28
0
Order By: Relevance
“…Lastly, our program is not entirely automated as the user is still required to manually export the raw video files, input scaling factors, and potentially alter the envelope threshold in the program. Even so, it is much quicker than manual analysis and similar to other non-coronary flow TTDE programs that have reduced time of analysis by 7.5-25 fold 14 , 20 , 22 . However, creating a fully automated program would reduce the analysis time even further.…”
Section: Discussionmentioning
confidence: 99%
See 1 more Smart Citation
“…Lastly, our program is not entirely automated as the user is still required to manually export the raw video files, input scaling factors, and potentially alter the envelope threshold in the program. Even so, it is much quicker than manual analysis and similar to other non-coronary flow TTDE programs that have reduced time of analysis by 7.5-25 fold 14 , 20 , 22 . However, creating a fully automated program would reduce the analysis time even further.…”
Section: Discussionmentioning
confidence: 99%
“… 14 and Zholgharni et al . 20 . The final resulting images were the full Doppler CFP sequence from the zero-velocity baseline to the maximum velocity and the full ECG recording ( Fig.…”
Section: Methodsmentioning
confidence: 99%
“…The two extracted velocity profiles were then used for detection of end‐diastolic and end‐systolic frames. Further details are provided in and elsewhere . The location of detected frames from the regional approach (auto‐septum) is plotted in Figure as blue square markers on the velocity profiles spanning three cardiac cycles.…”
Section: Methodsmentioning
confidence: 99%
“…Further details on this estimation method which we have also applied to the long strips of spectral Doppler traces can be found elsewhere. 15 To filter out the high-frequency noise, a low-pass first-order Butterworth digital filter was applied to the crude velocity profiles.…”
Section: Acknowledgmentsmentioning
confidence: 99%
“…They are Bland-Altman, Q-Q plot, and Density Function [6], [7]. Specifically and in contrast to the work presented by Zolgharni et al [8], the Bland-Altman method is utilized to validate the results of the new scheme or system. In this method, a check for the agreement between the data of the peak and time integral of the velocity in the context of clinical measurement will be conducted.…”
Section: Related Workmentioning
confidence: 99%