“…H 2 O 2 and CH 3 OOH * were measured with a wet chemical system based on the technique described by Lazrus et al (1985Lazrus et al ( , 1986. Ambient air is collected via a 1/2 PFA tubing embedded inside a stainless steel inlet system that is mounted front-facing on a side window of a Learjet 35A of GFD (Gesellschaft für Flugzieldarstellung, Hohn, Germany).…”
Section: Measurements Of H 2 O 2 and Ch 3 Ooh *mentioning
confidence: 99%
“…H 2 O 2 and CH 3 OOH * were measured with a wet chemical system based on the technique described by Lazrus et al (1985Lazrus et al ( , 1986. Ambient air is collected via a 1/2 PFA tubing embedded inside a stainless steel inlet system that is mounted front-facing on a side window of a Learjet 35A of GFD (Gesellschaft für Flugzieldarstellung, Hohn, Germany).…”
Section: Measurements Of H 2 O 2 and Ch 3 Ooh *mentioning
confidence: 99%
“…Measurement of hydrogen peroxide Among several methods for measurement of hydrogen peroxide, we adopted a following fluorometric method (Guilbault et al ., 1968) where p-hydroxyphenyl acetic acid (POPHA) was used as the substrate of peroxidase shown in reaction (1) An automated method based on this reaction was proposed with using a Technicon Auto analyzer system (Lazrus et al, 1986). Since air segmentation is required in the Technicon system, we changed to the flow injection analysis, which improved in reducing numbers of flow lines (the system is much simpler than that of Lazrus et al (1986), and thus, is much convenient to be used on shipboard) and run time (3 min.…”
Section: Methodsmentioning
confidence: 99%
“…Since air segmentation is required in the Technicon system, we changed to the flow injection analysis, which improved in reducing numbers of flow lines (the system is much simpler than that of Lazrus et al (1986), and thus, is much convenient to be used on shipboard) and run time (3 min. for one sample).…”
Section: Methodsmentioning
confidence: 99%
“…The H 2 O 2 instrument in the MCL was of the fluorimetric/ enzymatic type according to Lazrus et al 12 Due to a malfunction, the instrument did not operate during the ground-based checks. Instead, standard H 2 O 2 solutions were prepared from a stock solution which was titrated with a standard KMnO 4 solution and injected into the H 2 O 2 instruments.…”
Section: Mobile Calibration Laboratory (Mci)mentioning
confidence: 99%