2011
DOI: 10.1007/s10384-011-0107-2
|View full text |Cite
|
Sign up to set email alerts
|

Automated hyperemia analysis software: reliability and reproducibility in healthy subjects

Abstract: The software was simple to use and provided reproducible data. We established standard settings for the operation of the software. The use of our software will improve hyperemia evaluation, which is presently done using nonquantitative methods.

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
4
1

Citation Types

1
31
0

Year Published

2013
2013
2022
2022

Publication Types

Select...
4
2

Relationship

0
6

Authors

Journals

citations
Cited by 37 publications
(32 citation statements)
references
References 16 publications
1
31
0
Order By: Relevance
“…Thus, the ROI may have differed from patient to patient and from visit to visit, but not between photos of a patient's visit and of a CPT session, respectively. All photos were taken so as to capture the whole visible bulbar conjunctival space, so that the segmented ROI could be very large and cover as much as possible of the conjunctiva, unlike other methods using small ROIs of constant size and form [28]. Second, all images were modified by a four-filter system, which was integrated in the software and used to enhance color contrast, depict vessel edges and rims, and reduce background noise.…”
Section: Methodsmentioning
confidence: 99%
See 4 more Smart Citations
“…Thus, the ROI may have differed from patient to patient and from visit to visit, but not between photos of a patient's visit and of a CPT session, respectively. All photos were taken so as to capture the whole visible bulbar conjunctival space, so that the segmented ROI could be very large and cover as much as possible of the conjunctiva, unlike other methods using small ROIs of constant size and form [28]. Second, all images were modified by a four-filter system, which was integrated in the software and used to enhance color contrast, depict vessel edges and rims, and reduce background noise.…”
Section: Methodsmentioning
confidence: 99%
“…The current literature describes several achievements in digital image analysis of conjunctival vessels, which are reported to be more sensitive than subjective ratings [19,20,27,28,29,30,31,32,33,34,35,36]. Combinations of different techniques are described, such as threshold-setting, edge-detection, color extraction, smoothing, fractal analysis or densitometry [28,33].…”
Section: Introductionmentioning
confidence: 99%
See 3 more Smart Citations