2021
DOI: 10.1007/s00216-021-03481-7
|View full text |Cite
|
Sign up to set email alerts
|

Automated method to determine pharmaceutical compounds in wastewater using on-line solid-phase extraction coupled to LC-MS/MS

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
1
1
1

Citation Types

0
6
0

Year Published

2022
2022
2024
2024

Publication Types

Select...
6

Relationship

0
6

Authors

Journals

citations
Cited by 11 publications
(6 citation statements)
references
References 48 publications
0
6
0
Order By: Relevance
“…The limits of detection and quantification (LOQ) were estimated using the ratio of the blank standard deviation or the linear coefficient between the slope value of 3.3 and 10, respectively. Furthermore, for the LOQ (first point of the calibration curve), a relative standard deviation of less than 20% was adopted as an additional criterion to guarantee the reliability and quality of the results [ 36 ].…”
Section: Methodsmentioning
confidence: 99%
“…The limits of detection and quantification (LOQ) were estimated using the ratio of the blank standard deviation or the linear coefficient between the slope value of 3.3 and 10, respectively. Furthermore, for the LOQ (first point of the calibration curve), a relative standard deviation of less than 20% was adopted as an additional criterion to guarantee the reliability and quality of the results [ 36 ].…”
Section: Methodsmentioning
confidence: 99%
“…To investigate static adsorption, MMIPs or MNIPs (50 mg) were suspended in solutions (50 mL) of methcathinone with different concentrations (1-10 mg mL −1 ) and then shaken for 12 h at 35 °C. To examine the dynamic adsorption, MMIPs or MNIPs (50 mg) were suspended in 50 mL of methcathinone solution (2 mg mL −1 ) and incubated at 35 °C for different times (1,3,5,10,20,30,60,90,120, and 180 minutes). Subsequently, aer treatment with magnetic separation and enrichment, the adsorption capacity was calculated by analyzing the amount of methcathinone in the samples before and aer adsorption according to LC-MS/MS.…”
Section: Single and Competitive Batch Adsorption Testsmentioning
confidence: 99%
“…For example, Jin et al achieved quantitative analysis of abused substances in sewage based on SPE-LC-MS/ MS, demonstrating that the sensitivity of the method could be enhanced several times by the enrichment of SPE. 5,6 However, the method requires signicant amounts of energy for activation and elution, accurate control of ow rate and prolonged drying process, which makes enrichment process cumbersome, time-consuming (lasting several hours) and lacking in selectivity.…”
Section: Introductionmentioning
confidence: 99%
“…This integration does not necessarily mean the miniaturization of the system but rather how an analytical procedure is done [ 65 ]. On the other hand, hyphenation is an on-line blend between a chromatographic separation technique and one or more spectroscopic or spectrometric detection techniques leading to systems such as LC–MS, LC–MS/MS CE-MS, GC–MS, and LC-NMR [ 66 , 67 ].…”
Section: Integration Of Spe With Analytical Chromatographic Techniquesmentioning
confidence: 99%
“…Seawater was delivered to the SPE column via a quaternary pump and a six-port valve to switch between loading and elution to a UHPLC-MS/MS system. Marasco Júnior et al used a similar fashioned system of an Oasis HLB SPE column coupled to an LC–MS/MS system to determine pharmaceuticals in wastewater [ 66 ]. Most studies use similar setups resulting in high throughput, time-efficient, and less labor-intensive methods with improved speed and reliability [ 82 , 83 ].…”
Section: Integration Of Spe With Analytical Chromatographic Techniquesmentioning
confidence: 99%