Automated on-line SPE LC–MS/MS method to quantitate 6beta-hydroxycortisol and cortisol in human urine: Use of the 6beta-hydroxycortisol to cortisol ratio as an indicator of CYP3A4 activity
“…The ratio of 6-OHF/F in the period of 20:00-23:00 was significantly higher than other collection intervals (P < 0.05). The circadian variation in the ratio of 6-OHF/F observed in our lab is in general agreement with that observed by Ohno et al [16] and Barrett et al [17]. We find out a parallel diurnal rhythm in the urinary excretion of 6-OHF and F, with the lowest excretion rates observed in the period of 16:00-23:00 for both 6-OHF and F, in agreement with the results obtained by Lee [18] and Barrett et al [17].…”
“…The ratio of 6-OHF/F in the period of 20:00-23:00 was significantly higher than other collection intervals (P < 0.05). The circadian variation in the ratio of 6-OHF/F observed in our lab is in general agreement with that observed by Ohno et al [16] and Barrett et al [17]. We find out a parallel diurnal rhythm in the urinary excretion of 6-OHF and F, with the lowest excretion rates observed in the period of 16:00-23:00 for both 6-OHF and F, in agreement with the results obtained by Lee [18] and Barrett et al [17].…”
“…The limit of detection was 1 pg on column for both cortisol (S/N = 8) and 6-OHC (S/N = 6), which corresponds to a concentration of 0.01 ng/mL. This is more sensitive by more than a factor of 10 than the LC-MS/MS method with the Spark on-line SPE sample cleanup [10] that showed S/N = 10 for 0.2 ng/mL cortisol and S/N = 42 for 1 ng/mL 6-OHC.…”
Section: Lc-ms/ms Methods Validationmentioning
confidence: 94%
“…The most sensitive measurement was obtained in the negative ion mode by monitoring the transition of the adduct of cortisol or 6-OHC with the formic acid anion (m/z 407 or m/z 423) in the first quadrupole and the fragments m/z 331 for cortisol or m/z 347 for 6-OHC [10], corresponding to the loss of CH 2 O from the molecular ion after breakage between carbon atoms 20 and 21 of the steroid moiety [15]. The amount of urine used, injection volume and washing time over the trap column were optimized to give the best signal-to-noise ratio (S/N).…”
Section: Lc-ms/ms Methods Validationmentioning
confidence: 99%
“…More recently, an on-line solid phase extraction (SPE) LC-MS/MS method [10] was reported. It is based on a special on-line SPE equipment (Prospect-2 TM , Spark) that is not routinely available.…”
“…Method development for determining drug or metabolite concentrations from urine samples has been simplified with the implementation of on-line SPE. A sensitive method using on-line SPE and LC-MS/MS system for quantification of urinary cortisol metabolite and cortisol was developed and human urine sample were injected directly onto an on-line SPE apparatus followed by HPLC separation and LC-MS/MS detection (Barrett et al, 2005).…”
Section: Principles and Applications Of Lc-ms/ms For The Quantitativementioning
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.