2015
DOI: 10.1148/radiol.14141140
|View full text |Cite
|
Sign up to set email alerts
|

Automated Quantification of Right Ventricular Fat at Contrast-enhanced Cardiac Multidetector CT in Arrhythmogenic Right Ventricular Cardiomyopathy

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
1
1
1
1

Citation Types

3
17
1

Year Published

2015
2015
2023
2023

Publication Types

Select...
8
1

Relationship

2
7

Authors

Journals

citations
Cited by 24 publications
(21 citation statements)
references
References 24 publications
3
17
1
Order By: Relevance
“…The method used to segment intramyocardial fat from MDCT is based on previous validation studies demonstrating good correlation with contact mapping data 9 and Task Force criteria. 10 The distribution of RV fat is consistent with previous histological 3,24 and contact mapping studies. 18,25 In the current study, RV substrate was also assessed with the use of MRI.…”
Section: Distribution Of Structural Substrate In Arvcsupporting
confidence: 90%
See 1 more Smart Citation
“…The method used to segment intramyocardial fat from MDCT is based on previous validation studies demonstrating good correlation with contact mapping data 9 and Task Force criteria. 10 The distribution of RV fat is consistent with previous histological 3,24 and contact mapping studies. 18,25 In the current study, RV substrate was also assessed with the use of MRI.…”
Section: Distribution Of Structural Substrate In Arvcsupporting
confidence: 90%
“…Intramyocardial fat was defined as any myocardial voxel with attenuation less than −10 HU, based on previous validation versus contact mapping. 9 This substrate was segmented using an automated image processing method, as described previously, 9,10 and distributed over a biventricular 16-segment model: the RV and LV free walls comprised 7 segments each (3 segments at basal and midventricular levels-ie, anterior, lateral, and inferiorand 1 segment at the apex), and the septum comprised 2 segments (basal and midventricular). CMR imaging was performed on a 1.5T system (Avanto; Siemens Medical Solutions, Erlangen, Germany).…”
Section: Imagingmentioning
confidence: 99%
“…CT. Cardiac CT also provides a role in morphologic evaluation of the RV, particularly in patients with implantable cardioverter defibrillators who often cannot undergo MRI examination [80][81][82].…”
Section: Echocardiographymentioning
confidence: 99%
“…In patients with ARVC, the substrate was assessed on multidetector CT images by using automatic segmentation of right ventricular intramyocardial fat (18). On MR images, the endocardium and epicardium were segmented manually.…”
Section: Feasibilitymentioning
confidence: 99%