2015 International Siberian Conference on Control and Communications (SIBCON) 2015
DOI: 10.1109/sibcon.2015.7147128
|View full text |Cite
|
Sign up to set email alerts
|

Automated radiation test setup for functional and parametrical control of 8-bit microcontrollers

Abstract: The developed automated setup for functional and parametric control of 8-bit microcontrollers during radiation hardness tests is presented. The setup hardware is based on the NI modular instruments PXI-7841R and PXI-4110 operated under LabVIEW software. Test circuit and methods together with the user software structure and typical test results are presented.

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
3
1
1

Citation Types

0
10
0

Year Published

2016
2016
2016
2016

Publication Types

Select...
7

Relationship

0
7

Authors

Journals

citations
Cited by 17 publications
(10 citation statements)
references
References 18 publications
0
10
0
Order By: Relevance
“…The Figure 2 shows the front panel of the program. The program allows the waveform to be saved as a png file (Figure 3), and, as seen on Figure 2, can be easily integrated as a functional unit of the test system [6][7][8][9][10][11][12], and allows us to work with the oscilloscope remotely, if necessary [13].…”
Section: Description Of the Solutionmentioning
confidence: 99%
“…The Figure 2 shows the front panel of the program. The program allows the waveform to be saved as a png file (Figure 3), and, as seen on Figure 2, can be easily integrated as a functional unit of the test system [6][7][8][9][10][11][12], and allows us to work with the oscilloscope remotely, if necessary [13].…”
Section: Description Of the Solutionmentioning
confidence: 99%
“…A sample of MCU placed onto the PCB snap-in is connected to the switchboard, which provides connection between MCU pins and NI system channels, and also allows to set any logical state onto a MCU pins (pull-up, pull-down, high logical level, low logical level, connection to another line, Z-state) without NI system involving [10].…”
Section: Solutionmentioning
confidence: 99%
“…Usually the input control of the digital or analog integrated circuit is performed by automated systems or complexes of the functional and parametric control [9][10][11]. In this paper we describe the system of the parametrical and functional control for temperature sensor DS1624S+ [12].…”
Section: Introductionmentioning