Automated standard dilution analysis

Abstract: Automated standard dilution analysis provides rapid, accurate, and precise calibrations, correcting for both matrix effects and source fluctuations.

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
3
1
1

Citation Types

1
25
0

Year Published

2021
2021
2025
2025

Publication Types

Select...
6
1

Relationship

1
6

Authors

Journals

citations
Cited by 17 publications
(26 citation statements)
references
References 20 publications
1
25
0
Order By: Relevance
“…Similar improvements in trueness were observed when applying SDA to ICP-OES. [77][78][79][80] However, as expected, SDA-MIP-OES 0 instrumental LODs were higher than those calculated for SDA-ICP-OES. For example, LOD values calculated in similar conditions for Cr, Cu, Mn and Zn were 40, 10, 30 and 500 mg L À1 for SDA-MIP-OES, 75 and 5, 6, 7 and 10 mg L À1 for SDA-ICP-OES, 80 respectively.…”
Section: Calibration Strategiessupporting
confidence: 67%
See 3 more Smart Citations
“…Similar improvements in trueness were observed when applying SDA to ICP-OES. [77][78][79][80] However, as expected, SDA-MIP-OES 0 instrumental LODs were higher than those calculated for SDA-ICP-OES. For example, LOD values calculated in similar conditions for Cr, Cu, Mn and Zn were 40, 10, 30 and 500 mg L À1 for SDA-MIP-OES, 75 and 5, 6, 7 and 10 mg L À1 for SDA-ICP-OES, 80 respectively.…”
Section: Calibration Strategiessupporting
confidence: 67%
“…The unknown concentration of analyte in the sample (C sam ) is found from the slope and intercept of the calibration plot. 75 Additional details on, and new approaches to SDA which facilitate data processing and automation can be found elsewhere 77,78 The simultaneous matrix-matching and internal standardization nature of SDA provided signicant improvements in MIP-OES trueness, especially considering MIP's proneness to severe matrix effects. In beer analysis, for example, the average recovery for seven analytes was 113%, 117%, 122%, and 98% for the traditional EC, IS, SA, and for SDA, respectively.…”
Section: Calibration Strategiesmentioning
confidence: 99%
See 2 more Smart Citations
“…14 The preparation and mixing of S1 and S2 during automated SDA were initially carried out with a homemade mixing chamber and later optimized using a simple two channel pinch valve. 14,15…”
Section: Introductionmentioning
confidence: 99%