2017
DOI: 10.1109/jsen.2017.2701349
|View full text |Cite
|
Sign up to set email alerts
|

Automatic Detection of Seismocardiogram Sensor Misplacement for Robust Pre-Ejection Period Estimation in Unsupervised Settings

Abstract: Seismocardiography (SCG), the measurement of the local chest vibrations due to the movements of blood and the heart, is a non-invasive technique for assessing myocardial contractility via the pre-ejection period (PEP). Recently, SCG-based extraction of PEP has been shown to be an effective means of classifying decompensated from compensated heart failure patients, and thus can be potentially used for monitoring such patients at home. Accurate extraction of PEP from SCG signals hinges on lab-based population da… Show more

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
2
1

Citation Types

0
24
0

Year Published

2019
2019
2025
2025

Publication Types

Select...
7

Relationship

0
7

Authors

Journals

citations
Cited by 35 publications
(24 citation statements)
references
References 30 publications
0
24
0
Order By: Relevance
“…Most research groups applied conventional band-pass filters to remove baseline wandering, body movements, and breathing artefacts from SCG signals [26,36,38,41,45,46,55,[58][59][60][61][62][63]67,71,75,76,[78][79][80]82,93]. A few studies utilized or proposed more advanced noise removal techniques [64,76,88,[94][95][96].…”
Section: Noise Reductionmentioning
confidence: 99%
See 3 more Smart Citations
“…Most research groups applied conventional band-pass filters to remove baseline wandering, body movements, and breathing artefacts from SCG signals [26,36,38,41,45,46,55,[58][59][60][61][62][63]67,71,75,76,[78][79][80]82,93]. A few studies utilized or proposed more advanced noise removal techniques [64,76,88,[94][95][96].…”
Section: Noise Reductionmentioning
confidence: 99%
“…More studies are needed that compare different filtering methods in clinical and ambulatory settings. [26,36,38,41,45,46,55,[58][59][60][61][62][63]67,71,75,76,[78][79][80]82,93] Adaptive filtering Motion artefact removal [88,95] Averaging theory Motion artefact removal [101] Comb filtering Removing respiration noise from radar signal [50] Empirical mode decomposition Baseline wandering, breathing and body movement artefact removal [76,94,95] Independent component analysis Motion artefact removal [102] Median filtering [96] Morphological filtering [95] Polynomial smoothing Motion artefact removal [103] Savitzky-Golay filtering Motion artefact removal [83,103] Wavelet denoising Segmentation of HSs and SCG [64,95,96] Wiener filtering [94] 2.…”
Section: Noise Reductionmentioning
confidence: 99%
See 2 more Smart Citations
“…Seismocardiograms are typically obtained from MEMS accelerometers, firmly attached to the subject's chest, close to the sternum, by means of dedicated fixtures [11]. Some works explore different sensor placements over the chest wall, as reported in [12]; in [13], the impact of sensor placement on the estimation of Pre-Ejection Period (PEP, a relevant metric used in heart dynamics monitoring) is assessed. Reliable markers for cardiac activity were also found in gyroscope traces [14], a technique named GyroCardioGraphy (GCG).…”
Section: Related Workmentioning
confidence: 99%