Automatic Determination of Aortic Compliance With Cine-Magnetic Resonance Imaging

Abstract: The aortic compliance can be obtained from a fuzzy logic based automatic contouring method, thereby avoiding the important interobserver variation often associated with manual tracing.

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
1
1
1

Citation Types

0
14
0

Year Published

2003
2003
2023
2023

Publication Types

Select...
5
2

Relationship

1
6

Authors

Journals

citations
Cited by 27 publications
(14 citation statements)
references
References 33 publications
0
14
0
Order By: Relevance
“…2). An automatic method to detect aortic contour on each image has already been described (18). This automatic postprocessing allows an automatic determination of the aortic compliance, avoiding manual tracing that could be time-consuming and induces significant inter-and intra-observer variability.…”
Section: Image Analysismentioning
confidence: 99%
“…2). An automatic method to detect aortic contour on each image has already been described (18). This automatic postprocessing allows an automatic determination of the aortic compliance, avoiding manual tracing that could be time-consuming and induces significant inter-and intra-observer variability.…”
Section: Image Analysismentioning
confidence: 99%
“…From the change in crosssectional area between systole and diastole and an estimate of the corresponding intra-arterial pressure difference, the distensibility can be calculated. The latter has been done using magnetic resonance imaging [10,11] and ultrasound [12,13]. Ultrasound suffers from the difficulty of imaging all parts of the aorta in a single view.…”
Section: Introductionmentioning
confidence: 99%
“…To obtain further insight into the possibility of subclinical vascular abnormalities, aortic compliance was measured in 48 individuals (42 asymptomatic, 6 TAA/ PDA) with MRI, a very precise, noninvasive technique. 23 Our results show that aortic stiffness is an early hallmark of the disease, occurring in all subjects harboring the disease haplotype compared with their normal relatives.…”
Section: Discussionmentioning
confidence: 55%
“…It was measured by MRI with automatic detection of the contour of the aorta over the whole cardiac cycle as previously described. 23 Ascending aorta was imaged in the transverse plane at the level of the pulmonary trunk with a cine MRI sequence (ECG-gated cine FISP sequence) with a repetition time of 15 milliseconds. Forty to 60 images of a single slice were acquired, thereby covering the whole cardiac cycle.…”
Section: Automatic Determination Of Aortic Compliance With Cine Mrimentioning
confidence: 99%