Abstract: At present, Van Herick's method is a standard technique used to screen a Narrow Anterior Chamber Angle (NACA) and Angle-Closure Glaucoma (ACG). It can identify a patient who suffers from NACA and ACG by considering the width of peripheral anterior chamber depth (PACD) and corneal thickness. However, the screening result of this method often varies among ophthalmologists. So, an automatic screening of NACA and ACG based on slit-lamp image analysis by using Support Vector Machine (SVM) is proposed. SVM can autom… Show more

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
2
1

Citation Types

0
6
0

Year Published

2013
2013
2023
2023

Publication Types

Select...
4
1

Relationship

1
4

Authors

Journals

citations
Cited by 5 publications
(6 citation statements)
references
References 5 publications
0
6
0
Order By: Relevance
“…Theeraworm et al [15] increased the threshold of CT over PACD ratio to twice of VH as in her method the slit-lamp beam incidents did tend to be farther from LD. While there was no direct measurement of LD conducted, the new threshold derived based on analyzing classification's Receiver Operating Characteristics (ROC) curve of range of thresholds against gonioscopy results as ground truth.…”
Section: A Ld Role In Acd Measurementmentioning
confidence: 94%
See 4 more Smart Citations
“…Theeraworm et al [15] increased the threshold of CT over PACD ratio to twice of VH as in her method the slit-lamp beam incidents did tend to be farther from LD. While there was no direct measurement of LD conducted, the new threshold derived based on analyzing classification's Receiver Operating Characteristics (ROC) curve of range of thresholds against gonioscopy results as ground truth.…”
Section: A Ld Role In Acd Measurementmentioning
confidence: 94%
“…Then applied the traditional VH grading procedures to classify ACG. Theeraworn et al [15] went a step further, by introducing a slightly modified hardware. The slit-lamp and imaging device positions were switched, and angle increased from 60 degrees to 80 degrees.…”
Section: B Automatic Screening Anterior Chamber Depth and Angle Usinmentioning
confidence: 99%
See 3 more Smart Citations