2005
DOI: 10.1016/j.tws.2005.03.007
|View full text |Cite
|
Sign up to set email alerts
|

Axial load behaviour of high-strength rectangular concrete-filled steel tubular stub columns

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
1
1
1

Citation Types

1
50
0
5

Year Published

2006
2006
2023
2023

Publication Types

Select...
7
1

Relationship

1
7

Authors

Journals

citations
Cited by 178 publications
(56 citation statements)
references
References 8 publications
1
50
0
5
Order By: Relevance
“…The tests by Tan and Pu [9] show that compared with the ordinary CFST, the strength and plastic deformation of UHSC will be significantly improved due to the confinement effect of steel tube, the same as the bearing capacity of UHSCFST. The authors [10][11][12][13] also reached similar conclusions. However, Liew and Xiong [14,15] described that the UHSCFST has strong bearing capacity, but the load versus axial displacement curves tended to drop quickly after peak loads.…”
Section: Introductionsupporting
confidence: 59%
“…The tests by Tan and Pu [9] show that compared with the ordinary CFST, the strength and plastic deformation of UHSC will be significantly improved due to the confinement effect of steel tube, the same as the bearing capacity of UHSCFST. The authors [10][11][12][13] also reached similar conclusions. However, Liew and Xiong [14,15] described that the UHSCFST has strong bearing capacity, but the load versus axial displacement curves tended to drop quickly after peak loads.…”
Section: Introductionsupporting
confidence: 59%
“…본 장에서는 기존의 연구(Liu [11] , Liu 등 [12] , Liu와 Gho [13] , Varma 등 [14] )에 보고 된 실험 데이타베이스를 분석하여 각형강관이 제공하는 구 속효과를 평가 하였다. 이 분석에 사용된 실험 데이타베이스 는 아래와 같이 100MPa급 고강도콘크리트 및 834MPa급 고강도강재를 까지 넓은 범위를 포괄하고 있다:…”
Section: 기존 실험연구의 분석unclassified
“…RCFT기둥의 단주압축강도에 대한 Liu [11] , Liu 등 [12] 과 Liu와 Gho [13] 의 결과와 합치한다(Furlong [8] , Gourley 등 [9] , Schneider [16] ).…”
Section: 단주 압축강도unclassified
See 1 more Smart Citation
“…Test results also indicated that the provisions in EC4, ACI and AISC conservatively predicted the failure loads by 1%, 9% and 11%, respectively. Based on the test data of 26 stub columns with f y = 300-495 MPa and f c = 55-106 MPa, Liu and Gho [10] proposed a numerical model to estimate the axial load-shortening response of high-strength rectangular CFT columns. Furthermore, Liu [11] presented results of eccentric loading tests on 12 CFT slender columns.…”
Section: Previous Researchmentioning
confidence: 99%