Back-Flush Column-Switching Technique for on-Line Sample Cleanup and Enrichment to Determine Guaiphenesin in Human Serum

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
2
1

Citation Types

0
7
0

Year Published

2014
2014
2021
2021

Publication Types

Select...
5

Relationship

0
5

Authors

Journals

citations
Cited by 8 publications
(7 citation statements)
references
References 11 publications
0
7
0
Order By: Relevance
“…The validated method was applied to the measurement of enantiomers of both GUA and KET in human plasma samples after being fortified with different concentrations of GUA and KET (Table ). These concentrations were selected to cover the expected levels in clinical samples . Since both GUA and KET are found in plasma as the intact drugs and their metabolites are only excreted in urine, this gives a great advantage to the direct application of our proposed method to the monitoring of the drug levels in human plasma following actual administration of the studied combination (GUA and KET) to human volunteers.…”
Section: Resultsmentioning
confidence: 99%
See 3 more Smart Citations
“…The validated method was applied to the measurement of enantiomers of both GUA and KET in human plasma samples after being fortified with different concentrations of GUA and KET (Table ). These concentrations were selected to cover the expected levels in clinical samples . Since both GUA and KET are found in plasma as the intact drugs and their metabolites are only excreted in urine, this gives a great advantage to the direct application of our proposed method to the monitoring of the drug levels in human plasma following actual administration of the studied combination (GUA and KET) to human volunteers.…”
Section: Resultsmentioning
confidence: 99%
“…Since no change in response along with the absence of any degradation peaks was observed, the stability of GUA and KET prepared plasma samples for up to 24 h was proved. No long‐term stability studies were conducted here, as previous works have shown that KET and GUA have good stability in frozen samples.…”
Section: Resultsmentioning
confidence: 99%
See 2 more Smart Citations
“…The technique of the column switching technique combined with LC–MS makes biopharmaceutical analysis automatic, rapid, and efficient, and it has been widely used in complex biological matrix analysis with serum 30 , blood 31 , plasma 32 , urine 33 , and other matrices.…”
Section: New Technology Of On-line Biological Sample Processingmentioning
confidence: 99%