2012
DOI: 10.4172/2161-0665.s5-004
|View full text |Cite
|
Sign up to set email alerts
|

Balloon Aortic Valvuloplasty

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
4
1

Citation Types

0
45
2

Year Published

2017
2017
2023
2023

Publication Types

Select...
4
1

Relationship

0
5

Authors

Journals

citations
Cited by 7 publications
(47 citation statements)
references
References 62 publications
0
45
2
Order By: Relevance
“…Lababidi was also the first investigator to use this technique to the neonate with critical aortic valve stenosis [15]. Subsequently, a large number of papers on acute and medium-term follow-up results of balloon aortic valvuloplasty, extensively referenced elsewhere [1,[16][17][18][19][20], were published. The author's group was among the first to examine causes of restenosis after balloon aortic valvuloplasty [20] and call attention to the development of aortic insufficiency during follow-up [17].…”
Section: Historical Aspectsmentioning
confidence: 99%
“…Lababidi was also the first investigator to use this technique to the neonate with critical aortic valve stenosis [15]. Subsequently, a large number of papers on acute and medium-term follow-up results of balloon aortic valvuloplasty, extensively referenced elsewhere [1,[16][17][18][19][20], were published. The author's group was among the first to examine causes of restenosis after balloon aortic valvuloplasty [20] and call attention to the development of aortic insufficiency during follow-up [17].…”
Section: Historical Aspectsmentioning
confidence: 99%
“…Since the introduction of balloon valvuloplasty for valvar aortic stenosis in 1983, it has been used as a first therapeutic procedure for relief of aortic valve obstruction. Detailed description of the procedure of balloon valvuloplasty is beyond the scope of this paper, but is described elsewhere [29,30,31]. In brief, a balloon valvuloplasty catheter is positioned across the aortic valve and the balloon is inflated (Figure 3); the radial forces of balloon inflation produce disruption of valve leaflet fusion causing relief of aortic valve obstruction.…”
Section: Aortic Stenosismentioning
confidence: 99%
“…Sometimes, it is difficult to maintain the balloon across the aortic valve during balloon aortic valvuloplasty. In such situation, use of extra-stiff wires, longer balloons, double balloon technique, adenosine administration to produce cardiac standstill, and overdrive pacing have been used to accomplish a successful procedure [29,30,31]. In the author’s personal experience use of extra-stiff wires and longer balloons was helpful in carrying out the procedure with occasional need for overdrive pacing.…”
Section: Aortic Stenosismentioning
confidence: 99%
See 2 more Smart Citations