2010
DOI: 10.1089/vid.2010.0073
|View full text |Cite
|
Sign up to set email alerts
|

Barbed Suture for Renorrhaphy During Robot-Assisted Partial Nephrectomy

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
1
1
1

Citation Types

1
7
0
1

Year Published

2011
2011
2017
2017

Publication Types

Select...
7

Relationship

0
7

Authors

Journals

citations
Cited by 8 publications
(9 citation statements)
references
References 0 publications
1
7
0
1
Order By: Relevance
“…Encouraged with the success of UVA with barbed suture during VIP, we established its safety and feasibility of a two-layered, running closure of the collecting system and renal capsule during renorrhaphy, and significantly lowering WIT compared to standard polyglactin suture (18.5 vs. 24.7 min, respectively, p Z 0.008) [57]. As regional hypothermia would expand the window for duration of permissible ischemia, we successfully experimented with the GelPoint access platform to introduce ice-slush.…”
Section: Robotic Upper Tract and Renal Surgerymentioning
confidence: 99%
“…Encouraged with the success of UVA with barbed suture during VIP, we established its safety and feasibility of a two-layered, running closure of the collecting system and renal capsule during renorrhaphy, and significantly lowering WIT compared to standard polyglactin suture (18.5 vs. 24.7 min, respectively, p Z 0.008) [57]. As regional hypothermia would expand the window for duration of permissible ischemia, we successfully experimented with the GelPoint access platform to introduce ice-slush.…”
Section: Robotic Upper Tract and Renal Surgerymentioning
confidence: 99%
“…Bununla ilgili daha önce yapılmış çalışmalar KDDM ile geleneksel onarım veya düğümsüz teknikle yapılan çalış-malardır. Önceki bu çalışmalarda sıcak iskemi süresinin kısal-dığı rapor edilmiştir (%10 (21), %32 (22)) [21,22,23] . Bizim ça-lışmamızda da KDDM ile böbrek parankim onarımı yapılan hastalardaki sonuçların önceki çalışmalara paralel olduğu saptanmıştır (grup I: 23.81dk.…”
Section: Discussionunclassified
“…To date, the efficacy and safety of this novel suture in gynecologic (31)(32)(33)(34)(35), urologic (36)(37)(38) and orthopedic surgery (39) have been reported. With respect to digestive surgery though, only a few studies, including our 2011 report of the first use of barbed sutures in gastrointestinal anastomoses, have proven the safety and suitability of barbed sutures in terms of anastomotic leakages or stenosis, but there have been no prospective studies for bowel anastomosis following LG for malignant disease.…”
Section: Discussionmentioning
confidence: 99%