2006
DOI: 10.1152/ajpheart.00228.2006
|View full text |Cite
|
Sign up to set email alerts
|

Baroreceptor Reflex Sensitivity Estimated by the Sequence Technique is Reliable in Rats

Abstract: reflex control of heart rate in rats studied by induced and autogenic changes in arterial pressure. Am J Physiol Heart Circ Physiol 288: H2422-H2430, 2005. First published January 6, 2005 doi:10.1152/ ajpheart.00057.2004.-The function of the arterial baroreflex has traditionally been assessed by measurement of reflex changes in heart rate (HR) or sympathetic nerve activity resulting from experimenter-induced manipulation of arterial blood pressure (the Oxford method, also termed the pharmacological method). H… Show more

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
1
1
1
1

Citation Types

2
44
0
1

Year Published

2006
2006
2021
2021

Publication Types

Select...
8
1
1

Relationship

0
10

Authors

Journals

citations
Cited by 56 publications
(47 citation statements)
references
References 8 publications
2
44
0
1
Order By: Relevance
“…The slope of the regression line between spontaneous changes in AP and PI values is taken as an index of BRS, as is done when AP and PI changes are induced by vasoactive drug injections (37). The baroreflex nature of the PI/AP sequences has been demonstrated in cats (3), rats (38), and mice (20). This technique is particularly suitable to mice because these animals are not amenable to receive multiple intravenous injections.…”
Section: Discussionmentioning
confidence: 99%
“…The slope of the regression line between spontaneous changes in AP and PI values is taken as an index of BRS, as is done when AP and PI changes are induced by vasoactive drug injections (37). The baroreflex nature of the PI/AP sequences has been demonstrated in cats (3), rats (38), and mice (20). This technique is particularly suitable to mice because these animals are not amenable to receive multiple intravenous injections.…”
Section: Discussionmentioning
confidence: 99%
“…Arterial pressure was measured continuously via the telemetry catheter at 1,000 Hz, and sBRS was determined post hoc using the sequence method (Hemolab, Iowa City, IA) (4,52). From the arterial waveform, the software application identified ramps of heart beats in which systolic blood pressure and pulse interval both either increased or decreased.…”
Section: Determination Of Baroreflex Functionmentioning
confidence: 99%
“…From baseline recordings, spontaneous baroreceptor reflex sensitivity (SBRS) was calculated using the sequence method as described. 16 …”
mentioning
confidence: 99%