Batch and fixed-bed assessment of sulphate removal by the weak base ion exchange resin Amberlyst A21

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
3
1
1

Citation Types

0
20
0
1

Year Published

2015
2015
2024
2024

Publication Types

Select...
9
1

Relationship

0
10

Authors

Journals

citations
Cited by 68 publications
(21 citation statements)
references
References 16 publications
0
20
0
1
Order By: Relevance
“…If the dosed persulfate was completely decomposed, formed sulfate at concentrations of 800 mg/L and 1200 mg/L would be achieved when the dosages of persulfate were 1000 mg/L and 1500 mg/L, respectively. A sulfate concentration that is higher than 600 mg/L in drinking water might cause taste alteration and diarrhea [54]. However, it should be noted that the concentrations of M. aeruginosa in most source waters were always lower than 10 6 cells/mL.…”
Section: Effect Of Initial Ps Dose On Algae Removalmentioning
confidence: 96%
“…If the dosed persulfate was completely decomposed, formed sulfate at concentrations of 800 mg/L and 1200 mg/L would be achieved when the dosages of persulfate were 1000 mg/L and 1500 mg/L, respectively. A sulfate concentration that is higher than 600 mg/L in drinking water might cause taste alteration and diarrhea [54]. However, it should be noted that the concentrations of M. aeruginosa in most source waters were always lower than 10 6 cells/mL.…”
Section: Effect Of Initial Ps Dose On Algae Removalmentioning
confidence: 96%
“…The industrial wastewater is limited to under 500 mg/L sulfate in the legislation of many countries [13]. Several research have been reported for efficient removal of lead and sulfate from wastewater such as ion exchange [14][15][16], electrochemical reduction [17], activated carbon [18,19], biosorption [20], adsorption [21][22][23], and membrane separation [24]. The efficiency of these methods depends on the lead and sulfate concentration, pH, the economics involved, and social factor set in the standard of government agencies.…”
Section: Introductionmentioning
confidence: 99%
“…Bu modele göre qm değerleri Amberlite IRA 67 için 66,4; Amberlyst A23 için 281,2 ve Lewatit MonoPlus MP 62 için 796,1 mg/g olarak hesaplanmıştır [19]. Benzer sonuçlar Amberlyst A21 kullanılarak sulu çözeltilerden sülfat giderimi [29] ve reaktif boyaların Amberlite IRA-900 kullanılarak sulu çözeltilerden giderimi [30] için yapılan çalışmalardan da görülmektedir.…”
Section: Wawrzkiewicz Ve Hubicki Tarafından Remazolunclassified