2019
DOI: 10.1039/c9ra01987a
|View full text |Cite
|
Sign up to set email alerts
|

Batch microfabrication and testing of a novel silicon-base miniaturized reference electrode with an ion-exchanging nanochannel array for nitrite determination

Abstract: In this paper, a miniaturized Ag/AgCl reference electrode, which can be mass-produced by micro–nano manufacturing technology, was developed and demonstrated to have good stability and a long lifetime.

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
1
1

Citation Types

0
4
0

Year Published

2020
2020
2023
2023

Publication Types

Select...
7

Relationship

0
7

Authors

Journals

citations
Cited by 10 publications
(4 citation statements)
references
References 34 publications
0
4
0
Order By: Relevance
“…In miniaturized devices it has been introduced the silver wire/ink pseudoreference electrode, which apparently wins territory due to the formation of the natural oxide layer on the silver wire/ink, eliminating the leaking and solubility issues. In the following chapter, the fabrication process and they applicability of some miniaturized REs 28,29 will be presented.…”
Section: General Considerationsmentioning
confidence: 99%
See 2 more Smart Citations
“…In miniaturized devices it has been introduced the silver wire/ink pseudoreference electrode, which apparently wins territory due to the formation of the natural oxide layer on the silver wire/ink, eliminating the leaking and solubility issues. In the following chapter, the fabrication process and they applicability of some miniaturized REs 28,29 will be presented.…”
Section: General Considerationsmentioning
confidence: 99%
“…Amperometric sensors.-Amperometric microfabricated three electrode systems are a very good alternative for integrated electrochemical device, due to the fact that they are more stable than flexible electrochemical devices, and they are not disposable device like the integrated electrodes from the screen-printed family, where the ink is exfoliating when subjected to a cleaning procedure. In the last decade, electrochemical microfabricated electrodes (Table I) have been intensively used for the determination of heavy-metals, 16,[21][22][23][24][25]27 pollutants, 26,[28][29][30] drugs, 31,32,37 biomolecules, 35,39 oxygen 33 and hydrogen peroxide. 34 In 2010, Chen et al 21 proposed a microfabricated on-chip goldsilver-gold (Au-Ag-Au) three-electrode system for the determination of mercury ions.…”
Section: The Microfabrication and Applications Of Amperometric Devicesmentioning
confidence: 99%
See 1 more Smart Citation
“…Hence, the array with several sensor units was came up. Currently, although the metal-based and semiconductor-based traditional sensor array can realize the high-density arrangement of signal unit, it has no flexibility and cannot pressure applied on the blind area [37,38]. Thus, the flexible sensor array with high resolution and high sensitivity like real human skin is proposed and researched.…”
Section: Introductionmentioning
confidence: 99%