2022
DOI: 10.1039/d2sm00935h
|View full text |Cite
|
Sign up to set email alerts
|

Beating Poisson stochastic particle encapsulation in flow-focusing microfluidic devices using viscoelastic liquids

Abstract: The encapsulation and co-encapsulation of particles in microfluidic flows is essential in applications related to single-cell analysis and material synthesis. However, the whole encapsulation process is stochastic in nature, and...

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
1
1
1

Citation Types

21
49
1

Year Published

2022
2022
2024
2024

Publication Types

Select...
5
1

Relationship

2
4

Authors

Journals

citations
Cited by 15 publications
(71 citation statements)
references
References 36 publications
21
49
1
Order By: Relevance
“…A micromilling machine (Minitech CNC Mini-Mill) was used to fabricate the microfluidic device on a rigid polymethylmethacrylate (PMMA) substrate with a thickness of 1.2 mm, using the same approach employed in previous works. 16 Firstly, a 2-mm-wide tip was used to mill the substrate down to 300 µm to obtain a uniform surface. A 100 µm metal tip was used to mill the channel onto the PMAA substrate.…”
Section: Microfluidic Device Design and Fabricationmentioning
confidence: 99%
See 4 more Smart Citations
“…A micromilling machine (Minitech CNC Mini-Mill) was used to fabricate the microfluidic device on a rigid polymethylmethacrylate (PMMA) substrate with a thickness of 1.2 mm, using the same approach employed in previous works. 16 Firstly, a 2-mm-wide tip was used to mill the substrate down to 300 µm to obtain a uniform surface. A 100 µm metal tip was used to mill the channel onto the PMAA substrate.…”
Section: Microfluidic Device Design and Fabricationmentioning
confidence: 99%
“…Span 80 (Sigma Aldrich, UK), a non-ionic surfactant, was added at a concentration of 1 wt % to the oil to stabilize the interface between HA and oil, in agreement with previous works. 15,16 The viscosity of the mineral oil taken from the same batch employed here was previously measured to be 29 mPa•s. 15,16 The interfacial tension values between 0.1 wt % HA in PBS and mineral oil was here measured using a force tensiometer (Sigma 702, Biolin Scientific) equipped with a du Nouy ring.…”
Section: Sample Preparation and Characterizationmentioning
confidence: 99%
See 3 more Smart Citations