2013
DOI: 10.1134/s1819712413010091
|View full text |Cite
|
Sign up to set email alerts
|

Behavior and the catecholamine system of the brain in two generations of the descendants of male rats with chronic alcohol intoxication

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
1

Citation Types

2
1
0

Year Published

2014
2014
2020
2020

Publication Types

Select...
3

Relationship

0
3

Authors

Journals

citations
Cited by 3 publications
(3 citation statements)
references
References 7 publications
2
1
0
Order By: Relevance
“…5(B), but good recoveries from 95.6 to 105.7% were obtained, indicating that the proposed HPLC-CL method is applicable for the quantification of monoamine neurotransmitters in rat brain. The contents (mean ± SD) of NE, DA and 5-HT in rat brain were 0.60 ± 0.02, 0.67 ± 0.03 and 0.48 ± 0.03 ng/mg, which agree well with the reported data (Tsunoda and Funatsu, 2012;Zhu et al, 2011;Veretinskaya et al, 2013).…”
Section: Application To the Detection Of Monoamine Neurotransmitters supporting
confidence: 91%
See 1 more Smart Citation
“…5(B), but good recoveries from 95.6 to 105.7% were obtained, indicating that the proposed HPLC-CL method is applicable for the quantification of monoamine neurotransmitters in rat brain. The contents (mean ± SD) of NE, DA and 5-HT in rat brain were 0.60 ± 0.02, 0.67 ± 0.03 and 0.48 ± 0.03 ng/mg, which agree well with the reported data (Tsunoda and Funatsu, 2012;Zhu et al, 2011;Veretinskaya et al, 2013).…”
Section: Application To the Detection Of Monoamine Neurotransmitters supporting
confidence: 91%
“…It was reported that catecholamines were usually extracted by adsorption onto alumina because of attraction of the hydroxyl groups of catechol nucleus (Goldstein et al, 1981;Yi and Brown, 1991). The contents (mean ± SD) of NE, DA and 5-HT in rat brain were 0.60 ± 0.02, 0.67 ± 0.03 and 0.48 ± 0.03 ng/mg, which agree well with the reported data (Tsunoda and Funatsu, 2012;Zhu et al, 2011;Veretinskaya et al, 2013). The recoveries from alumina adsorption of NE, EP and DA were 55, 63 and 61%, respectively.…”
Section: Application To the Detection Of Monoamine Neurotransmitters supporting
confidence: 89%
“…The concentrations (mean ± SD) of NE and DA measured with the proposed HPLC‐CL method were 0.55 ± 0.03 and 0.69 ± 0.07 ng/mg tissue (rat brain, n = 3). These values agree with the reported data (Tagliamonte et al ., ; Finn et al ., ; Veretinskaya et al ., ). Therefore, the present study provides a new method for the detection of CAs in rat brain.…”
Section: Resultsmentioning
confidence: 97%