2020 International Conference on Smart Grids and Energy Systems (SGES) 2020
DOI: 10.1109/sges51519.2020.00110
|View full text |Cite
|
Sign up to set email alerts
|

Behavioural Study of a Remote Power System with High PV Penetration During a State of Emergency

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
1

Citation Types

0
3
0

Year Published

2021
2021
2022
2022

Publication Types

Select...
2
1
1

Relationship

2
2

Authors

Journals

citations
Cited by 4 publications
(3 citation statements)
references
References 12 publications
0
3
0
Order By: Relevance
“…Hence, economic analysis of the whole procedure is recommended to investigate the techno-economic feasibility of a microgrid consisting of PV-BESS systems [32]. As mentioned earlier, the HC of PV system for a specific power system can be defined as the amount of PV generation capacity (usually for distributed generation) integrated into the power system, above which the system's operating conditions are violated [10,[33][34][35]. The HC of PV in a network can be determined by an iterative method considering the system power factor, voltage regulation and equipment loading [33].…”
Section: Solar Pv Hosting: Performance Indices and Challenges In Remo...mentioning
confidence: 99%
See 1 more Smart Citation
“…Hence, economic analysis of the whole procedure is recommended to investigate the techno-economic feasibility of a microgrid consisting of PV-BESS systems [32]. As mentioned earlier, the HC of PV system for a specific power system can be defined as the amount of PV generation capacity (usually for distributed generation) integrated into the power system, above which the system's operating conditions are violated [10,[33][34][35]. The HC of PV in a network can be determined by an iterative method considering the system power factor, voltage regulation and equipment loading [33].…”
Section: Solar Pv Hosting: Performance Indices and Challenges In Remo...mentioning
confidence: 99%
“…The HC of PV in a network can be determined by an iterative method considering the system power factor, voltage regulation and equipment loading [33]. HC of the respective network also depends on the characteristics of the network, load and generation stream As mentioned earlier, the HC of PV system for a specific power system can be defined as the amount of PV generation capacity (usually for distributed generation) integrated into the power system, above which the system's operating conditions are violated [10,[33][34][35].…”
Section: Solar Pv Hosting: Performance Indices and Challenges In Remo...mentioning
confidence: 99%
“…During emergencies or in cases where a rapid power supply is required in response to a power supply failure, diesel generators may fail to turn ON immediately or ramp up the output as needed. Li-ion based batteries are well-proven technology to immediately take over and rapidly respond to the power requirements [15]. This study considers the energy required for the electrolysis in the Hydrogen generation plant, and the charging of the batteries would occur from the excess electricity of the microgrid, which would predominantly come from PV systems.…”
Section: The Proposed Systemmentioning
confidence: 99%