2020
DOI: 10.1007/s00216-020-02737-y
|View full text |Cite
|
Sign up to set email alerts
|

Bimetallic organic framework-based aptamer sensors: a new platform for fluorescence detection of chloramphenicol

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
1
1
1

Citation Types

0
11
0

Year Published

2020
2020
2024
2024

Publication Types

Select...
8

Relationship

0
8

Authors

Journals

citations
Cited by 22 publications
(11 citation statements)
references
References 47 publications
0
11
0
Order By: Relevance
“…The biosensor used in this study only consisted of one aptamer and two split probes. The preparation was easy and the requirements for storage conditions were lower compared with ternary Ag2CrO4/g-C3N4/GO nanocomposite 15 , fluorochrome 16 , labeled oligonucleotide 17 , bimetallic organic framework 18 , GO-QDs nanocomposites and enzyme-linked aptamers 19 , and gold nanoparticles 20 in previous studies. The simple reaction system of our assay also resulted in a lower cost, about 0.16 dollars per reaction (the cost included oligonucleotide synthesis, reagents, and consumables).…”
Section: Detection Limit and Linear Detection Range Of The Biosensormentioning
confidence: 96%
See 1 more Smart Citation
“…The biosensor used in this study only consisted of one aptamer and two split probes. The preparation was easy and the requirements for storage conditions were lower compared with ternary Ag2CrO4/g-C3N4/GO nanocomposite 15 , fluorochrome 16 , labeled oligonucleotide 17 , bimetallic organic framework 18 , GO-QDs nanocomposites and enzyme-linked aptamers 19 , and gold nanoparticles 20 in previous studies. The simple reaction system of our assay also resulted in a lower cost, about 0.16 dollars per reaction (the cost included oligonucleotide synthesis, reagents, and consumables).…”
Section: Detection Limit and Linear Detection Range Of The Biosensormentioning
confidence: 96%
“…Thus, they show good potential in the detection of pathogens 13 , metal ions 14 and antibiotics including CAP 10 . As with antibodies, aptamers targeting CAP always combine with other indicators or catalytic labels such as ternary Ag2CrO4/g-C3N4/GO nanocomposite 15 , fluorochrome 16 , labeled oligonucleotide 17 , bimetallic organic framework 18 , GO-QDs nanocomposites 19 , and gold nanoparticles 20 . However, they are still insufficiently sensitive, complex in preparation or dependent on specifical equipment.…”
Section: Introductionmentioning
confidence: 99%
“…Relying on the strong adsorption and fluorescence quenching ability of MOF, two dye-based fluorescent sensing strategies were explored for CAP. , Lu et al successfully prepared the bimetallic organic framework nanomaterial Cu/UiO-66 by coordinate bonding of MOF UiO-66 with Cu 2+ and established a fluorescence method for the quantitative detection of CAP using phosphate and ROX double-labeled aptamers and Cu/UiO-66 . The method displayed low fluorescence background, good reproducibility, and high sensitivity with LOD of 0.09 nM (30 pg mL –1 ).…”
Section: Application Of Fluorescent Aptasensor For the Detection Of F...mentioning
confidence: 99%
“…Aptamers are highly comparable to antibodies, although they show several advantages, such as cheap chemical fabrication, superior stability, and high reproducibility. Despite these unique properties, these molecules have been scarcely incorporated in MOF supports for sample treatment purposes due to their relatively short existence time [ 62 , 63 , 64 , 65 , 66 ]. Lin and co-workers [ 62 , 63 ] developed two aptamer-MOF devices for the selective extraction of polychlorinated biphenyls (PCBs) in soil and fish samples followed by GC-MS analysis.…”
Section: Applications Of Affinity-based Mof Materials In Sample Trmentioning
confidence: 99%
“…Additionally, aptamer-functionalized MOF materials have been applied for food safety purposes [ 65 , 66 ]. As an example, Zhang et al [ 65 ] synthesized a magnetic MOF (MIL-101) coupled with an aptamer for the enrichment of ochratoxin A in corn and peanut samples, and the determination was followed by UHPLC-MS-MS.…”
Section: Applications Of Affinity-based Mof Materials In Sample Trmentioning
confidence: 99%