2021
DOI: 10.1016/j.energy.2020.119336
|View full text |Cite
|
Sign up to set email alerts
|

Binary-objective optimization of latest low-GWP alternatives to R245fa for organic Rankine cycle application

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
3
1
1

Citation Types

0
7
0

Year Published

2021
2021
2024
2024

Publication Types

Select...
9

Relationship

0
9

Authors

Journals

citations
Cited by 36 publications
(7 citation statements)
references
References 21 publications
0
7
0
Order By: Relevance
“…The drop-in assessment is performed considering potential drop-in replacements with VCC and COP values within 25% of the reference refrigerant to be replaced. It should be mentioned that for R1336mzz­(Z) and R1224yd­(Z), the COP is predicted as an average based on available experimental data under similar conditions, , due to the nonavailability of isothermal ideal gas entropies needed to compute the TS-diagrams involved in the COP calculations. The COP values for these refrigerants are within those obtained for highly efficient refrigerants R1233zd­(E) and R245fa.…”
Section: Resultsmentioning
confidence: 99%
“…The drop-in assessment is performed considering potential drop-in replacements with VCC and COP values within 25% of the reference refrigerant to be replaced. It should be mentioned that for R1336mzz­(Z) and R1224yd­(Z), the COP is predicted as an average based on available experimental data under similar conditions, , due to the nonavailability of isothermal ideal gas entropies needed to compute the TS-diagrams involved in the COP calculations. The COP values for these refrigerants are within those obtained for highly efficient refrigerants R1233zd­(E) and R245fa.…”
Section: Resultsmentioning
confidence: 99%
“…In this study, the thermodynamic and economic performance of the system is investigated considering the three organic working fluids selected. The following working fluids are studied and compared, R245fa, R1234yf, and R1234ze, which were found to be appropriate fluids for low-temperature waste heat recovery (Yang et al, 2021) and are suitable fluids according to the criteria mentioned above. Some physical properties of the studied working fluids (e.g., boiling and critical temperature, specific heat of liquid and vapor, GWP and ODP) are collected in published article (Dokl et al, 2021).…”
Section: Description Of Orc Systemmentioning
confidence: 99%
“…The final preferred solution is then determined by the concept of ‘weight’, which reflects the preference of the decision-maker. Yang et al [ 23 ] carried out the binary-objective optimization of low-GWP alternatives to R245fa for the ORC system. The results showed that both the cycle thermal efficiency and the LECT (total savings of levelized electricity cost) are sensitive to evaporator outlet temperature.…”
Section: Introductionmentioning
confidence: 99%