2015
DOI: 10.1002/ccd.26278
|View full text |Cite
|
Sign up to set email alerts
|

Biological effect on drug distribution and vascular healing via paclitaxel‐coated balloon technology in drug eluting stent restenosis swine model

Abstract: ObjectivesTo evaluate the biological effect of a paclitaxel‐coated balloon (PCB) technology on vascular drug distribution and healing in drug eluting stent restenosis (DES‐ISR) swine model.BackgroundThe mechanism of action and healing response via PCB technology in DES‐ISR is not completely understood.MethodsA total of 27 bare metal stents were implanted in coronary arteries and 30 days later the in‐stent restenosis was treated with PCB. Treated segments were harvested at 1 hr, 14 days and 30 days post treatme… Show more

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
3
2

Citation Types

0
9
0

Year Published

2017
2017
2022
2022

Publication Types

Select...
8
1

Relationship

1
8

Authors

Journals

citations
Cited by 11 publications
(9 citation statements)
references
References 22 publications
0
9
0
Order By: Relevance
“…OCT is emerging as a very important imaging device for the evaluation of coronary plaque characteristics and neointimal proliferation after stenting due to its high-resolution. Recent animal and human data 18,19) validated this tool in the evaluation of peri-strut neointimal formation and coverage. In addition, recent studies suggest that the different characteristics of neointimal tissue seen by OCT may correlate with clinical events such as late stent thrombosis.…”
Section: Discussionmentioning
confidence: 96%
“…OCT is emerging as a very important imaging device for the evaluation of coronary plaque characteristics and neointimal proliferation after stenting due to its high-resolution. Recent animal and human data 18,19) validated this tool in the evaluation of peri-strut neointimal formation and coverage. In addition, recent studies suggest that the different characteristics of neointimal tissue seen by OCT may correlate with clinical events such as late stent thrombosis.…”
Section: Discussionmentioning
confidence: 96%
“…Previous studies reported OCT-documented late vessel healing and enlargement after DCB angioplasty. 5,6) In animal models, paclitaxel-eluting stent exhibited greater neointimal area and medial necrosis, due to a reduction in endothelial and smooth muscle cells, at follow-up. 7) Similar mechanisms may underlie late vessel healing and enlargement after DCB angioplasty in human coronary arteries.…”
Section: Discussionmentioning
confidence: 99%
“…Typically, arterial levels of paclitaxel rapidly decline 72 hours after balloon delivery and fall below therapeutic levels by 180 days. 20 First in-human clinical studies using different PCB technologies demonstrate that PCB decreases angiographic restenosis by 40% to 50% by 6 months after initial delivery compared with PTA. 21,22 However, randomized controlled studies suggest that the effect on restenosis and vessel patency declines after the first 12 months.…”
Section: Discussionmentioning