Order By: Relevance
“…In cortical bone -the values of maximum v. Mises stress are higher on the loading side. The highest value of 7.57 MPa is on the middle (angled) implant 15 , and the anterior 25 has slightly lower values of 6.85 MPa. In the cortical bone around the distal implant 5, the values of maximum v. Mises stress are the lowest, 2.91 MPa.…”
Section: Implant -Loading Sitementioning
confidence: 91%
See 2 more Smart Citations
“…In cortical bone -the values of maximum v. Mises stress are higher on the loading side. The highest value of 7.57 MPa is on the middle (angled) implant 15 , and the anterior 25 has slightly lower values of 6.85 MPa. In the cortical bone around the distal implant 5, the values of maximum v. Mises stress are the lowest, 2.91 MPa.…”
Section: Implant -Loading Sitementioning
confidence: 91%
“…On implants -On the loading side, the highest values of maximum v. Mises stress are on the middle implant 15 with values of 21.9 MPa, and on the front implant 25 with values of 31.3 MPa. The distal implant 5 on the same side has much lower values, less than 3.90 MPa.…”
Section: Implant -Loading Sitementioning
confidence: 99%
See 1 more Smart Citation
“…Most of the stress is found at the crestal region, as opposed to the apical part. [149] The maximum occlusal force for a complete denture wearer ranges from 5 -50 lb. People with implant-supported fixed prostheses can increase their maximum bite force by 85% within 2 months of implant treatment; it may further increase by more than 300% after 3 years.…”
Section: Occlusal Forcesmentioning
confidence: 99%
“…The implant body has a high tendency to slide if shear force is applied and is considered to be the most unfavourable force, as it can cause damage to implants and the surrounding bone. [113,149] 2.7 Patient reported outcomes (PROs)…”
Section: Occlusal Forcesmentioning