Biomedical soft contact-lens sensor for in situ ocular biomonitoring of tear contents

Abstract: A soft contact-lens biosensor (SCL-biosensor) for novel non-invasive biomonitoring of tear fluids was fabricated and tested. Wearing a biosensor on eye enabled the in situ monitoring of tear contents. The biosensor has an enzyme immobilized electrode on the surface of a polydimethyl siloxane (PDMS) contact lens. The SCL-biosensor was fabricated using microfabrication techniques for functional polymers (PDMS and 2-methacryloyloxyethyl phosphorylcholine (MPC) polymer). In investigation of in vitro characterizati… Show more

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
1
1
1
1

Citation Types

1
43
0

Year Published

2014
2014
2023
2023

Publication Types

Select...
6
2

Relationship

2
6

Authors

Journals

citations
Cited by 78 publications
(44 citation statements)
references
References 37 publications
1
43
0
Order By: Relevance
“…However, most strip‐based sensors are fabricated on partially flexible substrates, which may cause eye irritation . In this case, soft‐contact‐lens‐based wireless sensors have been developed to solve the above limitations.…”
Section: Applicationsmentioning
confidence: 99%
See 1 more Smart Citation
“…However, most strip‐based sensors are fabricated on partially flexible substrates, which may cause eye irritation . In this case, soft‐contact‐lens‐based wireless sensors have been developed to solve the above limitations.…”
Section: Applicationsmentioning
confidence: 99%
“…However,most strip-based sensors are fabricated on partially flexible substrates, which may cause eye irritation. [74][75][76] In this case, soft-contact-lens-based wireless sensors have been developed to solve the above limitations. Parviz's group has designed contact lens glucose sensors based on wireless electronics,w hicha re now developed by Google.…”
Section: Tear-based Analysismentioning
confidence: 99%
“…The peak current indicates instillation of glucose (Figure 2–). The inverse peak indicates dilution of tear glucose by instillation of physiological sodium chloride solution . The tear turnover was calculated using semi‐log regression curve.…”
Section: Contact Lens Sensors In Conjunctiva Sacmentioning
confidence: 99%
“…In recent years, significant effort has been focused on sampling and analysis of alternative body fluids, such as interstitial fluid [5], tears [6], saliva [7], and sweat [8]. The transition from blood to other body fluids provides a less invasive means of sampling, which in turn may provide a route to facilitate longer-term continuous monitoring.…”
Section: Parameters Of Interestmentioning
confidence: 99%