2016
DOI: 10.1109/tbme.2015.2484379
|View full text |Cite
|
Sign up to set email alerts
|

Biomimetic Accommodating Intraocular Lens Using a Valved Deformable Liquid Balloon

Abstract: A deformable liquid-filled lens can significantly improve accommodation over the presbyopic natural lens.

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
1
1
1

Citation Types

0
6
0

Year Published

2019
2019
2022
2022

Publication Types

Select...
7

Relationship

0
7

Authors

Journals

citations
Cited by 9 publications
(6 citation statements)
references
References 25 publications
0
6
0
Order By: Relevance
“…Others seem to achieve an increased level of spectacle independence, but principally from pseudoaccommodative mechanisms such as multifocality, rather than a change in optical power (Pepose et al, 2017a). Newer designs (few that have been clinically tested) include dual optics, shape changing optics and refractive index changing optics (Ben-Nun and DeBoer et al, 2016;McCafferty and Schwiegerling, 2015;Tomas-Juan and Murueta-Goyena Larranaga, 2015). The latter research on possible future advances in 'accommodating' implants is discussed in section 7.…”
Section: 'Accommodating' Iolsmentioning
confidence: 99%
“…Others seem to achieve an increased level of spectacle independence, but principally from pseudoaccommodative mechanisms such as multifocality, rather than a change in optical power (Pepose et al, 2017a). Newer designs (few that have been clinically tested) include dual optics, shape changing optics and refractive index changing optics (Ben-Nun and DeBoer et al, 2016;McCafferty and Schwiegerling, 2015;Tomas-Juan and Murueta-Goyena Larranaga, 2015). The latter research on possible future advances in 'accommodating' implants is discussed in section 7.…”
Section: 'Accommodating' Iolsmentioning
confidence: 99%
“…Currently, we are using a gel lens; however, it is not soft enough. Several researchers (DeBoer et al [ 17 ]) suggest using a deformable liquid balloon lens, which is softer than a gel lens. However, if a softer lens is used, there could be a relatively greater problem related to astigmatism.…”
Section: Resultsmentioning
confidence: 99%
“…In this way, the liquid IOL could obtain the ability to alter the shape, thus processing the effect of adjusting the refractive power, which was also called accommodation IOL. The relative research in this area is brought by Deboer et al (2015) . They introduced a deformable PDMS lens shell filled with a transparent liquid.…”
Section: Advances In Intraocular Lens Optical Materialsmentioning
confidence: 99%