2016
DOI: 10.1002/adv.21564
|View full text |Cite
|
Sign up to set email alerts
|

Bis‐GMA Free Dental Materials Based on UDMA/SR833s Dental Resin System

Abstract: ABSTRACT:Tricyclododecane dimethanol diacrylate (SR833s) was used to replace triethylene glycol dimethacrylate (TEGDMA) as a diluent monomer and mixed with 1,6-bis(methacryloxy-2-ethoxy-carbonylamino)-2,4,4-trimethylhexane (UDMA) to prepare 2,2-bis[4-(2-hydroxy-3-methacryloyloxypropyl)-phenyl]propane (Bis-GMA) free dental resin system, and commonly used BaAlSiO 2 dental microfillers were added into UDMA/SR833s resin to prepare Bis-GMA free dental composites. Physicochemical properties such as double bond conve… Show more

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
2
1

Citation Types

1
8
0

Year Published

2018
2018
2021
2021

Publication Types

Select...
8

Relationship

3
5

Authors

Journals

citations
Cited by 14 publications
(9 citation statements)
references
References 40 publications
1
8
0
Order By: Relevance
“…That was why EC-4 with 15 wt.% of IBOA had higher DC than EC-1 without IBOA and EC-2 with 5 wt.% of IBOA. This result was consistent with previous research that, when used as a replacement for TEGDMA, SR833s could reduce DC of dental resin while IBOA could maintain it [ 12 , 13 , 19 ]. However, the first-tested hypothesis that low-shrinkage composite resins would promote a similar degree of conversion and lower shrinkage behavior compared to the conventional composite resin formulation was partially rejected.…”
Section: Discussionsupporting
confidence: 93%
See 1 more Smart Citation
“…That was why EC-4 with 15 wt.% of IBOA had higher DC than EC-1 without IBOA and EC-2 with 5 wt.% of IBOA. This result was consistent with previous research that, when used as a replacement for TEGDMA, SR833s could reduce DC of dental resin while IBOA could maintain it [ 12 , 13 , 19 ]. However, the first-tested hypothesis that low-shrinkage composite resins would promote a similar degree of conversion and lower shrinkage behavior compared to the conventional composite resin formulation was partially rejected.…”
Section: Discussionsupporting
confidence: 93%
“…However, compared with bis -GMA (shrinkage as 5.2%), TEGDMA (shrinkage as 12.5%) has much higher volumetric shrinkage, thus using diluents with lower volumetric shrinkage is an effective way to reduce overall shrinkage of resin matrices [ 11 ]. Tricyclo (5.2.1.0) decanedimethanol dacrylate (SR833s) and isobornyl acrylate (IBOA) are two kinds of low-viscous acrylate monomers reported as substitutes for TEGDMA in resin matrices with the aim of reducing volumetric shrinkage, but their influences on polymerization shrinkage behavior of dental composite resins has not yet been investigated [ 12 , 13 ].…”
Section: Introductionmentioning
confidence: 99%
“…It is important to underline that the final properties result not only from the characteristics of individual monomers, but above all, from the interactions that arise in the monomer mixture and the characteristics of the resulting polymer network [ 24 ]. Recent research has examined new monomers based on methacrylate, urethanes, or new resin systems [ 19 , 20 , 25 , 26 , 27 , 28 , 29 ]. However, only a few commercial materials, such as Venus Diamond (Heraeus Kulzer), Kalore (GC Corp), and SDR (Dentsply Sirona), are based on such modified monomers [ 30 , 31 ].…”
Section: Discussionmentioning
confidence: 99%
“…VS was measured by using a modification of the method previously published 35) . The specimens' densities (n=6) were measured to determine VS according to Archimedes' principle with a commercial Density Accessory Kit of the analytical balance (XS105, Mettler Toledo, Greifensee, Switzerland).…”
Section: Volume Shrinkage (Vs)mentioning
confidence: 99%