Bismuth sulfide microstructures decorated with functionalized boron nitride composite for electrochemical detection of sulfadiazine

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
1
1
1

Citation Types

0
5
0

Year Published

2023
2023
2024
2024

Publication Types

Select...
9

Relationship

2
7

Authors

Journals

citations
Cited by 13 publications
(5 citation statements)
references
References 42 publications
0
5
0
Order By: Relevance
“…The calibration plot shown in Figure b shows the correlation coefficient of lower concentration of I pa , R 2 = 0.991, and higher concentration of I pa , R 2 = 0.9965. Based on eq the limit of detection (LOD) was calculated: LOD = 3 σ / S where S is the slope from the linear range and σ indicates the deviation of the blank (S/N = 3). The LOD was estimated using this equation and was found to be 2.1 nM.…”
Section: Resultsmentioning
confidence: 99%
“…The calibration plot shown in Figure b shows the correlation coefficient of lower concentration of I pa , R 2 = 0.991, and higher concentration of I pa , R 2 = 0.9965. Based on eq the limit of detection (LOD) was calculated: LOD = 3 σ / S where S is the slope from the linear range and σ indicates the deviation of the blank (S/N = 3). The LOD was estimated using this equation and was found to be 2.1 nM.…”
Section: Resultsmentioning
confidence: 99%
“…A couple from the glassy electrode series were modified using boron nitride (BN) with bismuth sulfide (Bi 2 S 3 ) or titanium carbide (TiC). 102,105 Most glassy carbon based electrodes were modified with binary metal oxides nanoparticles such as lanthanum cerate (LaCe NPs), gadolinium vanadate (GdVO 4 ), zinc manganite (ZnMn 2 O 4 ), and samarium vanadate (SmV) with or without carbon-based nanomaterials like carbon nanofibers (CNF) and graphene oxide (GO). Of these, wide linear concentration range and low LOD values were observed for ZnMn 2 O 4 /GCE and SmV/ CNF/GCE due to an increased surface area and improved electronic conductivity.…”
Section: Electrochemical Sensors Used For the Determination Of Topica...mentioning
confidence: 99%
“…6b shows the correlation coefficient of R 2 = 0.9930 (lower concentrations) and R 2 = 0.9938 (higher concentrations). The diagnostic characteristics of the fabricated device in the linear range of 0.5-89.38 mM and the limit of detection (LOD) determined to be 0.02 mM based on LOD = 3 Â (standard deviation of low concentration)/(slope of the calibration plot) [31][32][33] were analysed. These improved electrochemical properties have such a wide range of applications in identifying different types of environmental contaminants for individual monitoring.…”
Section: Dpv Different Concentration Analysismentioning
confidence: 99%