2015
DOI: 10.3390/toxins7051544
|View full text |Cite
|
Sign up to set email alerts
|

Botulinum Neurotoxin Serotypes Detected by Electrochemical Impedance Spectroscopy

Abstract: Botulinum neurotoxin is one of the deadliest biological toxins known to mankind and is able to cause the debilitating disease botulism. The rapid detection of the different serotypes of botulinum neurotoxin is essential for both diagnosis of botulism and identifying the presence of toxin in potential cases of terrorism and food contamination. The modes of action of botulinum neurotoxins are well-established in literature and differ for each serotype. The toxins are known to specifically cleave portions of the … Show more

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
5

Citation Types

0
16
0

Year Published

2016
2016
2024
2024

Publication Types

Select...
4
2

Relationship

1
5

Authors

Journals

citations
Cited by 17 publications
(16 citation statements)
references
References 37 publications
0
16
0
Order By: Relevance
“…The main advantage being that they allow for a high sensitivity to be achieved in relation to surface interactions and changes [94]. Some of the areas in which these methodologies are being utilised include sensors for various biomarkers [95,96,97] and toxins [98], along with pathogens [99,100]; this is not only due to the high levels of sensitivity, but also because these techniques yield rapid detection times compared to the mouse bio-assay [101]. Both cyclic voltammetry (CV) and electrochemical impedance spectroscopy (EIS) have been utilised in the development of BoNT sensors [94,101].…”
Section: Methods Of Detectionmentioning
confidence: 99%
See 4 more Smart Citations
“…The main advantage being that they allow for a high sensitivity to be achieved in relation to surface interactions and changes [94]. Some of the areas in which these methodologies are being utilised include sensors for various biomarkers [95,96,97] and toxins [98], along with pathogens [99,100]; this is not only due to the high levels of sensitivity, but also because these techniques yield rapid detection times compared to the mouse bio-assay [101]. Both cyclic voltammetry (CV) and electrochemical impedance spectroscopy (EIS) have been utilised in the development of BoNT sensors [94,101].…”
Section: Methods Of Detectionmentioning
confidence: 99%
“…Some of the areas in which these methodologies are being utilised include sensors for various biomarkers [95,96,97] and toxins [98], along with pathogens [99,100]; this is not only due to the high levels of sensitivity, but also because these techniques yield rapid detection times compared to the mouse bio-assay [101]. Both cyclic voltammetry (CV) and electrochemical impedance spectroscopy (EIS) have been utilised in the development of BoNT sensors [94,101]. Briefly, in CV a charge can be measured that relates to the number of species on a working electrode that are able to be oxidised, as well as the number of electrons involved in the oxidation [102].…”
Section: Methods Of Detectionmentioning
confidence: 99%
See 3 more Smart Citations