2016
DOI: 10.1039/c5sm02546j
|View full text |Cite
|
Sign up to set email alerts
|

Boundary flow on end-grafted PEG brushes

Abstract: We investigated the boundary conditions for flow of a Newtonian liquid over soft interfaces by measuring hydrodynamic drainage forces with colloid probe atomic force microscopy in a viscous liquid. The investigated soft surfaces are end-grafted brushes of thiolated poly(ethylene glycol) (PEG), of molecular weight 1k and 30k, grafted-to gold. The conditions for brush preparation were optimized as to meet the stringent conditions required for surface force measurements, namely reproducible and uniform surface co… Show more

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
2
1

Citation Types

1
35
0

Year Published

2017
2017
2020
2020

Publication Types

Select...
6

Relationship

0
6

Authors

Journals

citations
Cited by 23 publications
(36 citation statements)
references
References 60 publications
1
35
0
Order By: Relevance
“…The three dashed lines indicate the range of spring parameter and elasticity investigated here. The shaded areas represent experimental configuration of prior experimental studies for reduced modulus of the soft coating between 0.5-10 MPa, where purple: Charrault et al 8 , blue: Kaveh et al 7 red: Wang et al 12 , and grey: Honig et al 39 A slope of 0.8 in log-log scale is illustrated in the bottom right corner. The green regime above the green dashed line indicates…”
Section: Results and Discussion Choice And Relevance Of Parameters Invmentioning
confidence: 99%
See 4 more Smart Citations
“…The three dashed lines indicate the range of spring parameter and elasticity investigated here. The shaded areas represent experimental configuration of prior experimental studies for reduced modulus of the soft coating between 0.5-10 MPa, where purple: Charrault et al 8 , blue: Kaveh et al 7 red: Wang et al 12 , and grey: Honig et al 39 A slope of 0.8 in log-log scale is illustrated in the bottom right corner. The green regime above the green dashed line indicates…”
Section: Results and Discussion Choice And Relevance Of Parameters Invmentioning
confidence: 99%
“…7,8,12,39 For each experimental configuration ( R ,  , V , k ) the shaded areas show how changing the modulus of the coating, from 0.5 MPa to 10 MPa (elastomers), would change K and  . Lowering the elasticity further would bring most experimental conditions into the K   regime, which is solved here.…”
Section: Results and Discussion Choice And Relevance Of Parameters Invmentioning
confidence: 99%
See 3 more Smart Citations