2000
DOI: 10.1002/(sici)1522-2586(200002)11:2<195::aid-jmri18>3.0.co;2-q
|View full text |Cite
|
Sign up to set email alerts
|

Breath-hold 3D gradient-echo MR imaging of the lung parenchyma: Evaluation of reproducibility of image quality in normals and preliminary observations in patients with disease

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
3
1
1

Citation Types

0
31
0
5

Year Published

2000
2000
2016
2016

Publication Types

Select...
8
1

Relationship

2
7

Authors

Journals

citations
Cited by 47 publications
(36 citation statements)
references
References 15 publications
0
31
0
5
Order By: Relevance
“…Vogt et al [27] compared HF-FSE MRI to conventional chest radiography and revealed a sensitivity for nodules 5-10 mm of 94.9% and 97.4% for nodules >11 mm using HF-FSE MRI. Semelka et al [28] assessed a nodular detection threshold of 3 mm using a 3D-GRE protocol similar to the one used in our study.…”
Section: Discussionmentioning
confidence: 99%
“…Vogt et al [27] compared HF-FSE MRI to conventional chest radiography and revealed a sensitivity for nodules 5-10 mm of 94.9% and 97.4% for nodules >11 mm using HF-FSE MRI. Semelka et al [28] assessed a nodular detection threshold of 3 mm using a 3D-GRE protocol similar to the one used in our study.…”
Section: Discussionmentioning
confidence: 99%
“…Images from patients referred for abdominal MRI clearly delineated the mediastinum and the lower parts of the lung, as far as they were covered. These results already suggested, that a high imaging quality and negligible image artifacts could be expected [13].…”
Section: Discussionmentioning
confidence: 99%
“…The overall imaging quality was at least comparable to 2D-GRE studies of the lung [2 ± 4,16]. Ghosting artifacts from cardiac and vessel pulsation, which are generally very strong on coronal 2D-GRE images, were absent or only moderate on our 3D-GRE (VIBE) series [13,16]. Pre-saturation pulses to suppress the influence from moving mediastinal structures -sometimes used for 2D-GRE protocols requiring additional imaging time [16] ± were not necessary.…”
Section: Discussionmentioning
confidence: 99%
“…Gadolinium-enhanced images are also necessary for MR assessment of the lungs. The 3D gradientecho T1-weighted sequence with fat suppression used in this protocol show diminished phase artifact in the retrocardiac region in comparison to two-dimensional gradient-echo T1-weighted images, allowing for better evaluation of all portions of the lung (14,17,25) . The pulmonary vasculature can also be evaluated with this sequence because of its high spatial resolution, which enables high-quality multiplanar reconstruction.…”
Section: B a C Dmentioning
confidence: 99%