2017
DOI: 10.1136/flgastro-2016-100796
|View full text |Cite
|
Sign up to set email alerts
|

BSPGHAN Motility Working Group position statement: paediatric multichannel intraluminal pH impedance monitoring—indications, methods and interpretation

Abstract: MII-pH is increasingly used by paediatricians as the diagnostic tool for assessing gastro-oesophageal reflux disease and symptom association. There is wide variation in paediatric practice and a need for standardised practice.

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
1
1
1
1

Citation Types

0
25
0
1

Year Published

2017
2017
2024
2024

Publication Types

Select...
8
2

Relationship

0
10

Authors

Journals

citations
Cited by 26 publications
(26 citation statements)
references
References 31 publications
0
25
0
1
Order By: Relevance
“…The age appropriate catheter (Pediatric ZandorpH catheter with 1 Antimony and 6 impedance rings with 2 cm interval, Laborie, The Netherlands) was inserted after EGD and under general anesthesia. When the patient woke up, the catheter position was adjusted to place pH sensor at 2 vertebraes above the diaphragm from a plain chest x-ray in upright and full inspired position, followed the statement from British Society of Paediatric Gastroenterology, Hepatology and Nutrition (BSPGHAN) motility working group[ 10 ]. All chest X-ray was reviewed by a pediatric gastroenterologist (Sintusek P) to confirm the proper position.…”
Section: Methodsmentioning
confidence: 99%
“…The age appropriate catheter (Pediatric ZandorpH catheter with 1 Antimony and 6 impedance rings with 2 cm interval, Laborie, The Netherlands) was inserted after EGD and under general anesthesia. When the patient woke up, the catheter position was adjusted to place pH sensor at 2 vertebraes above the diaphragm from a plain chest x-ray in upright and full inspired position, followed the statement from British Society of Paediatric Gastroenterology, Hepatology and Nutrition (BSPGHAN) motility working group[ 10 ]. All chest X-ray was reviewed by a pediatric gastroenterologist (Sintusek P) to confirm the proper position.…”
Section: Methodsmentioning
confidence: 99%
“…Multichannel intraluminal impedance combined with pH (MII‐pH) detects acid, weak acid and non-acid reflux episodes and is superior to pH metry 38. MII-pH monitoring is now becoming the investigation of choice for diagnosing GOR 39…”
Section: Discussionmentioning
confidence: 99%
“…Die Impedanzmessung (sogenannte "multichannel intraluminal impedance") ist der pH-Metrie zwar überlegen, sie ist jedoch nicht standardisiert. Weiterhin existieren keine Normalwerte für diese aufwendige Methode [62]. Die Röntgenuntersuchung mit Refluxtestung (sogenannter "Breischluck") erlaubt den Ausschluss anatomischer Pathologien wie einer Hiatushernie oder Malrotation (4 % der Fälle).…”
Section: Gastroösophageale Refluxkrankheit (Görk)unclassified