Calculation of the spatial resolution in two-photon absorption spectroscopy applied to plasma diagnosis

Abstract: Articles you may be interested inA new spectrometer design for the x-ray spectroscopy of laser-produced plasmas with high (sub-ns) time resolutiona) Rev. Sci. Instrum. 85, 11D627 (2014) We report a detailed characterization of the spatial resolution provided by two-photon absorption spectroscopy suited for plasma diagnosis via the 1S-2S transition of atomic hydrogen for optogalvanic detection and laser induced fluorescence (LIF). A precise knowledge of the spatial resolution is crucial for a correct interpreta… Show more

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
1
1
1

Citation Types

0
6
0
3

Year Published

2017
2017
2021
2021

Publication Types

Select...
5
1

Relationship

1
5

Authors

Journals

citations
Cited by 9 publications
(9 citation statements)
references
References 17 publications
0
6
0
3
Order By: Relevance
“…Cathode Anode when moderate laser energy below 45 J is used, i.e. an irradiance of 150 MW/cm 2 is applied in the overlapping volume [23]. Exceeding this irradiance, the measured spectra suffer an additional broadening of the Stark components due to the depletion of the atomic ground state density and the life time reduction of the 2S level caused by photo-ionization, which, however, have no significant influence on the E-field determination when working in pure hydrogen plasmas [24].…”
Section: Plasma Source Mouvementmentioning
confidence: 99%
See 1 more Smart Citation
“…Cathode Anode when moderate laser energy below 45 J is used, i.e. an irradiance of 150 MW/cm 2 is applied in the overlapping volume [23]. Exceeding this irradiance, the measured spectra suffer an additional broadening of the Stark components due to the depletion of the atomic ground state density and the life time reduction of the 2S level caused by photo-ionization, which, however, have no significant influence on the E-field determination when working in pure hydrogen plasmas [24].…”
Section: Plasma Source Mouvementmentioning
confidence: 99%
“…In previous papers [20][21][22], we reported the determination of the strong E-field strength (ranging from about 0.5 to 4 kV/cm) in the cathode fall region of a hollow cathode discharge (HCD), operated in hydrogen (H), via the Stark splitting of the 1S -2S transition, with a noteworthy high spatial resolution [23]. Doppler-free two-photon excitation combined with optogalvanic detection is employed to measure the E-field of the HCD in a wide range of discharge parameters.…”
Section: Introductionmentioning
confidence: 99%
“…El solapamiento se realiza en una conguración foco con foco, con un ángulo de 1,53 o limitado por la geometría del experimento, con el n de conseguir una irradiancia mayor y también que las medidas sean lo más locales posibles mejorando así la resolución espacial. Como se verá en el capítulo 3, un estudio detallado [143] demuestra que el volumen de solapamiento es del orden de 100 µm y 10 mm de longitud.…”
Section: Generación De Radiación Ultravioletaunclassified
“…En la gura 3.6 se muestra como ejemplo un conjunto de esos espectros para un cátodo de 10 mm de diámetro, presión de 600 Pa y corriente de 100 mA, recogidos a distintas distancias de la pared del cátodo, indicadas en la Una posible explicación que se dio para este ensanchamiento adicional fue la resolución espacial proporcionada por el solapamiento de los dos haces láser, que entonces se estimaba en 30 mm de longitud y una anchura de 200 µm en el centro del solapamiento, basándose en la geometría del experimento. Para conocer en detalle cómo este solapamiento afectaba a la resolución del experimento, se adquirió la cámara UV LaserCam-HR UV-Coherent (descrita en el capítulo 2) y con los perles extraídos se realizó un estudio detallado cuyos resultados se recogen en [143,156].…”
Section: Inuencia De La Energía Láser En La Determinación Del Campo Eunclassified
See 1 more Smart Citation