1973
DOI: 10.1103/physreva.8.3045
|View full text |Cite
|
Sign up to set email alerts
|

Calculations of Effusive-Flow Patterns. II. Scattering Chambers with Semi-Infinite Slits

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
2
1

Citation Types

2
18
0

Year Published

1984
1984
2018
2018

Publication Types

Select...
8
2

Relationship

0
10

Authors

Journals

citations
Cited by 48 publications
(20 citation statements)
references
References 8 publications
2
18
0
Order By: Relevance
“…Another inevitable error comes from the effusion of target molecules through orifices of the scattering cell leading to inhomogeneity of target density in the reaction volume and to elongation of the effective path over which the scattering events take place. 10 We also noticed that the increasing contamination of the electron optics elements with the target molecules causes a gradual drift in the energy scale during the experiment. The energy drift, by about 0.1 eV, is especially troublesome at low electron-impact energies where the TCS may change steeply with the energy and/or has resonant-like structures.…”
Section: Methodsmentioning
confidence: 84%
“…Another inevitable error comes from the effusion of target molecules through orifices of the scattering cell leading to inhomogeneity of target density in the reaction volume and to elongation of the effective path over which the scattering events take place. 10 We also noticed that the increasing contamination of the electron optics elements with the target molecules causes a gradual drift in the energy scale during the experiment. The energy drift, by about 0.1 eV, is especially troublesome at low electron-impact energies where the TCS may change steeply with the energy and/or has resonant-like structures.…”
Section: Methodsmentioning
confidence: 84%
“…Taking into account theoretical elastic differential cross sections [19,20,26], we found that the measured TCS can be lowered by 4-5% around 3 eV, about 2-3% within tor nL in the BBL formula we followed the method adopted from Ref. [33] to the present experimental conditions. The calculations show that both aforementioned effects nearly compensate and the estimated uncertainty of nL is about 2-3%, taking also into account the uncertainty in the pressure measurements.…”
Section: B Uncertainty Analysismentioning
confidence: 99%
“…Following the electron path-length calculations [38], we have estimated that the denominator pL in the BBL formula, taken as the product of the pressure, p, measured in the center of the cell and the geometrical distance (L = 30.5 mm) between entrance and exit cell apertures, may be erroneous to within 2%.…”
Section: Measurementsmentioning
confidence: 99%