2007
DOI: 10.4314/wsa.v32i1.5237
|View full text |Cite
|
Sign up to set email alerts
|

Calibration of a frequency-domain reflectometer for determining soil-water content in a clay loam soil

Abstract: A soil-water frequency domain reflectometry sensor, the ThetaProbe, was evaluated for its ability to measure the apparent soil dielectric constant and subsequent estimation of soil-water content. The soil-water content of a clay-loam soil, determined using factory-supplied parameters for the sensor and soil-estimated parameters, was compared to the soil-water content determined in the laboratory. The range in soil-water content was from 0.20 to 0.42 m 3 ·m -3. A total of 78 soil samples from the 0 to 600 mm de… Show more