2021
DOI: 10.1088/1748-0221/16/05/p05016
|View full text |Cite
|
Sign up to set email alerts
|

Calibration of the energy response matrix for X-ray detector CCD236

Abstract: CCD236 is a new generation swept charge device (SCD) developed by e2v. It is designed for the Low Energy Telescope (LE) onboard the Hard X-ray Modulation Telescope (HXMT). The spectrum of the detector is a convolution result of the incident spectrum and the energy response of the detector. One can obtain accurate quantities of incident spectrum by fitting the model spectrum with the energy response. According to the two-dimensional interpolation method, an energy response matrix of CCD236 is generated using th… Show more

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
1
1
1

Citation Types

0
5
0

Year Published

2022
2022
2024
2024

Publication Types

Select...
6
1

Relationship

1
6

Authors

Journals

citations
Cited by 9 publications
(5 citation statements)
references
References 21 publications
0
5
0
Order By: Relevance
“…One of the crystals, like KAP/Si111/Si220/Si440, can be installed and replaced on the monochromator so as to cover 1∼40 keV. As Figure 8 shows, this source has been successfully Article Title applied in the energy response calibration of the CCD236 detector of the Low Energy Telescope onboard HXMT [14]. To calibrate the timing performance of the detector and telescope system, a modulated X-ray source was developed [15] and verified.…”
Section: X-ray Sourcesmentioning
confidence: 99%
“…One of the crystals, like KAP/Si111/Si220/Si440, can be installed and replaced on the monochromator so as to cover 1∼40 keV. As Figure 8 shows, this source has been successfully Article Title applied in the energy response calibration of the CCD236 detector of the Low Energy Telescope onboard HXMT [14]. To calibrate the timing performance of the detector and telescope system, a modulated X-ray source was developed [15] and verified.…”
Section: X-ray Sourcesmentioning
confidence: 99%
“…One of the crystals, like KAP/Si111/Si220/Si440, can be installed and replaced on the monochromator so as to cover 1∼40 keV. As Figure 8 shows, this source has been successfully applied in the energy response calibration of the CCD236 detector of the Low Energy Telescope onboard HXMT [17].…”
Section: X-ray Sourcesmentioning
confidence: 99%
“…[10,11] To address today's energy market needs for sustainability in industry and transportation, "Green Hydrogen" produced from renewables plays a pivotal role in decarbonization. [12][13][14] In addition to these developments in industry, there are also various lab-based efforts worldwide including, plasmolysis of water/water vapors, reforming of alcohols, biohydrogen (based on microalgae), or chemical cycles [15][16][17][18][19][20] There is no doubt that hydrogen is one of the key tools in energy transition, and it has a very significant effect on CO 2 emission reductions (6%) according to NZE Scenario. IEA reported in the Global Hydrogen Review that ≈90 Mt H 2 was produced worldwide in 2020, where 80% of this amount was produced from fossil resources.…”
Section: Current Status Of Hydrogen Production and Challengesmentioning
confidence: 99%