2019
DOI: 10.3390/s19092043
|View full text |Cite
|
Sign up to set email alerts
|

Cantilever Sensors

Abstract: A cantilever is considered the most basic mechanical spring-mass system and has enormous application potential for sensors [...]

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
1

Citation Types

0
2
0
1

Year Published

2020
2020
2022
2022

Publication Types

Select...
3
1

Relationship

0
4

Authors

Journals

citations
Cited by 4 publications
(3 citation statements)
references
References 7 publications
0
2
0
1
Order By: Relevance
“…In CFM (Clear and Nealey 1999;Takano et al, 1999;Okabe et al, 2000;Fiorini et al, 2001;Kreller et al, 2002;Brewer and Leggett 2004;Gourianova et al, 2005;Cameron et al, 2006;Dague et al, 2007;Dufrene 2008;Foster et al, 2009;Sirghi et al, 2009;Barattin and Voyer 2011;Teobaldi et al, 2011;Alsteens et al, 2012;Picas et al, 2012;Beaussart et al, 2014;Hibino and Nakano-Nishida 2014), cantilever tips are chemically functionalized with particular functional groups for performing specific functions in a system. CFM relies on two approaches: microcantilever-based biosensors (MC-B) (Subramanian and Catchmark 2007;Lang and Gerber 2008;Gruber et al, 2011;Johnson and Mutharasan 2012;Peiner and Wasisto 2019;Bennett et al, 2020;Lee and Lee 2020;Mamou et al, 2021) and nanomechanical cantilever sensors (NCS) to achieve these goals of characterizing and understanding the system at single-molecule level with high reproducibility and repeatability. The microcantilever-based biosensing utilizes the specific binding of biomolecules for analytical sensing.…”
Section: Afm As Biosensormentioning
confidence: 99%
See 1 more Smart Citation
“…In CFM (Clear and Nealey 1999;Takano et al, 1999;Okabe et al, 2000;Fiorini et al, 2001;Kreller et al, 2002;Brewer and Leggett 2004;Gourianova et al, 2005;Cameron et al, 2006;Dague et al, 2007;Dufrene 2008;Foster et al, 2009;Sirghi et al, 2009;Barattin and Voyer 2011;Teobaldi et al, 2011;Alsteens et al, 2012;Picas et al, 2012;Beaussart et al, 2014;Hibino and Nakano-Nishida 2014), cantilever tips are chemically functionalized with particular functional groups for performing specific functions in a system. CFM relies on two approaches: microcantilever-based biosensors (MC-B) (Subramanian and Catchmark 2007;Lang and Gerber 2008;Gruber et al, 2011;Johnson and Mutharasan 2012;Peiner and Wasisto 2019;Bennett et al, 2020;Lee and Lee 2020;Mamou et al, 2021) and nanomechanical cantilever sensors (NCS) to achieve these goals of characterizing and understanding the system at single-molecule level with high reproducibility and repeatability. The microcantilever-based biosensing utilizes the specific binding of biomolecules for analytical sensing.…”
Section: Afm As Biosensormentioning
confidence: 99%
“…Major controllers of sensitivity (produced by irreversible interactions) are the degree of uniformity of the sensor surface coating and external stimuli affecting the molecular reorganization. Few studies where NCS (Fagan et al, 2000;Mertens et al, 2019;Peiner and Wasisto 2019) was used efficiently to achieve this goal are mentioned here. For example, adsorption of gas can cause bending and deflection of functionalized cantilever.…”
Section: Afm As Biosensormentioning
confidence: 99%
“…Биохимические анализаторы состава газообразных и жидких смесей, основанные на технологиях MEMS и NEMS, привлекают внимание многих исследователей уже около двух десятков лет. Заметное место в ряду таких измерительных средств занимают сенсоры на основе микрокантилеверов (МК) [1][2][3][4][5][6][7][8][9][10][11][12]. Информационным сигналом таких сенсоров является резонансная частота собственных колебаний МК, которая весьма просто преобразуется в цифровой сигнал.…”
Section: Introductionunclassified