2022
DOI: 10.1002/biot.202100325
|View full text |Cite
|
Sign up to set email alerts
|

Capillary and microchip electrophoresis method development for amino acid monitoring during biopharmaceutical cultivation

Abstract: The increased use of biopharmaceuticals calls for improved means of bioprocess monitoring. In this work, capillary electrophoresis (CE) and microchip electrophoresis (MCE) methods were developed and applied for the analysis of amino acids (AAs) in cell culture supernatant. In samples from different days of a Chinese hamster ovary cell cultivation process, all 19 proteinogenic AAs containing primary amine groups could be detected using CE, and 17 out of 19 AAs using MCE. The relative concentration changes in di… Show more

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
1
1
1

Citation Types

0
3
0

Year Published

2023
2023
2024
2024

Publication Types

Select...
5
1

Relationship

1
5

Authors

Journals

citations
Cited by 8 publications
(3 citation statements)
references
References 24 publications
0
3
0
Order By: Relevance
“…Using micellar electrokinetic chromatography could enhance separation due to the extra separation mechanism introduced by the micelles, therefore, SDS was included as a factor in the design. In addition, compatibility with other methods developed for the integrated platform such as amino acid analysis [46] would improve. The boric acid concentration, the SDS concentration, and the pH were varied in the ranges 80–160 mM, 0–100 mM, and 8.5–9.5, respectively.…”
Section: Resultsmentioning
confidence: 99%
“…Using micellar electrokinetic chromatography could enhance separation due to the extra separation mechanism introduced by the micelles, therefore, SDS was included as a factor in the design. In addition, compatibility with other methods developed for the integrated platform such as amino acid analysis [46] would improve. The boric acid concentration, the SDS concentration, and the pH were varied in the ranges 80–160 mM, 0–100 mM, and 8.5–9.5, respectively.…”
Section: Resultsmentioning
confidence: 99%
“…The detection results of exosomes [1] and heavy metals [2] samples show the wide application of ME. However, the overlapping peaks problem [3], [4], [5], [6] is a serious challenge for ME signal analysis. Thus, to accurately measure component peaks in ME signals, further research is needed on the analysis of low-resolution overlapping peaks.…”
Section: Ieee Transactions On Instrumentation and Measurementmentioning
confidence: 99%
“…In view of the miniature scale of microchip electrophoresis (MCE), it is suitable for high throughput screening of biomarkers in metabolomics. It improves the selectivity and sensitivity of the MS for the detection and separation of metabolites by the combination of MCE with highresolution MS (HRMS) [202]. In mouse serum, Sah et al [203] targeted the metabolites associated with high-grade S5 for an overview of the CE and MCE applications.…”
Section: Microchip Capillary Electrophoresismentioning
confidence: 99%